Statistical reconstruction of x-ray CT images from energy-integrated signals: A simulation study

被引:0
|
作者
Lasio, G
Whiting, B
Williamson, J
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
[2] Mallinckrodt Inst Radiol, St Louis, MO USA
关键词
D O I
10.1118/1.1998252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Statistical reconstruction (SR) algorithms have the potential to significantly reduce X‐ray CT image artifacts due to a more realistic model of the detector signal acquisition process. Most SR algorithms assume that the CT detectors are photon‐counting devices and generate Poisson‐distributed signals. However, actual CT detectors integrate energy and exhibit compound Poisson distributed signal statistics. The goal of this study is to assess the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram and the reconstruction algorithm. Method and Materials: A 2D CT projection simulator software was created to generate synthetic polyenergetic transmission data assuming i) photon‐count signals with simple Poisson distribution and ii) energy‐weighted compound Poisson distributed signals. An Alternating Minimization (AM) algorithm was used to reconstruct images from the data models i) and ii) for a typical abdominal scan protocol and for incident particle fluence levels ranging from 105 to 1.6×106 photons/detector. The phantoms simulated included normal soft tissue, bone, and metal inserts. The images reconstructed from data models i) and ii) were compared by visual inspection and quantitative image‐quality measures. Results: Substantial streaking artifacts appear in images formed from energy‐integrated data when the AM algorithm assumes a particle‐fluence spectrum Φ̄0(E). Once AM's spectrum is replaced by the energy‐fluence spectrum E ⋅Φ̄ (E), AM correctly predicts the data means and eliminates the artifacts. With the energy‐weighted spectrum, the reconstructed image quality from data models i) and ii) does not differ significantly even when SNR is very low. Conclusion: Mismatch between the actual and assumed CT detector signal statistics does not significantly degrade image quality once systematic data means mismatches are corrected. Within the context of statistical image reconstruction, there appears to be no benefit to develop more complex statistical reconstruction algorithms based upon energy‐integrating detector signal statistics models. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [21] Noise simulation in x-ray CT
    Massoumzadeh, P
    Earl, OA
    Whiting, BR
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 898 - 909
  • [22] Fluid simulation and X-ray CT images for soot deposition in a diesel filter
    K. Yamamoto
    S. Satake
    H. Yamashita
    N. Takada
    M. Misawa
    The European Physical Journal Special Topics, 2009, 171 : 205 - 212
  • [23] Fluid simulation and X-ray CT images for soot deposition in a diesel filter
    Yamamoto, K.
    Satake, S.
    Yamashita, H.
    Takada, N.
    Misawa, M.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2009, 171 : 205 - 212
  • [24] FBP initialization for transition artifacts reduction in statistical X-ray CT reconstruction.
    Zbijewski, W
    Beekman, FJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2970 - 2972
  • [25] A Splitting-Based Iterative Algorithm for Accelerated Statistical X-Ray CT Reconstruction
    Ramani, Sathish
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 677 - 688
  • [26] Statistical reconstruction for X-ray micro-CT systems with noncontinuous detectors.
    Zbijewski, Wojciech
    Beekman, Freek J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2323 - 2326
  • [27] Simulation study on a photon counting X-ray CT system
    Ogawa, K
    Shibusawa, H
    Harata, Y
    Yamakawa, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2755 - 2759
  • [28] Sparse reconstruction methods in X-ray CT
    Abascal, J. F. P. J.
    Abella, M.
    Mory, C.
    Ducros, N.
    de Molina, C.
    Marinetto, E.
    Peyrin, F.
    Desco, M.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [29] Ordered subset reconstruction for x-ray CT
    Beekman, FJ
    Kamphuis, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07): : 1835 - 1844
  • [30] Iterative reconstruction methods in X-ray CT
    Beister, Marcel
    Kolditz, Daniel
    Kalender, Willi A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 94 - 108