Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences

被引:152
|
作者
Reichert, ILH
Robson, MD
Gatehouse, PD
He, TG
Chappell, KE
Holmes, J
Girgis, S
Bydder, GM [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Charing Cross Hosp, Dept Orthoped Surg, Imperial Coll, Fac Med, London W6 8RF, England
[3] Royal Brompton Hosp, Cardiac Meagnet Resonance Unit, London SW3 6NP, England
[4] Univ Oxford, Dept Cardiovasc Med, Ctr Clin Magnet Resonance Res, Oxford OX1 2JD, England
[5] MRC, Ctr Clin Sci, Imaging Sci Dept, Robert Steiner Magnet Resonance Unit, London W12 0HS, England
[6] Hammersmith Hosp, Fac Med, Imperial Coll, Dept Med, London W12 0HS, England
关键词
magnetic resonance imaging; cortical bone; ultrashort echo time; bone perfusion;
D O I
10.1016/j.mri.2005.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Normal adult cortical bone has a very short T-2 and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone in human subjects and use this signal to characterise this tissue. Subjects and Methods: Seven volunteers and 10 patients were examined using ultrashort TE pulse sequences (TE = 0.07 or 0.08 ms). Short and long inversion as well as fat suppression pulses were used as preparation pulses. Later echo images were also obtained as well as difference images produced by subtracting a later echo image from a first echo image. Saturation pulses were used for T-1 measurement and sequences with progressively increasing TEs for T-2* measurement. Intravenous gadodiamide was administered to four subjects. Results: Signal in cortical bone was detected with UTE sequences in children, normal adults and patients. This signal was usually made more obvious by subtracting a later echo image from the first provided that the signal-to-noise ratio was sufficiently high. Normal mean adult T(1)s ranged from 140 to 260 ms, and mean T-2*s ranged from 0.42 to 0.50 ms. T-1 increased significantly with age (P < .01). Increased signal was observed after contrast enhancement in the normal volunteer and the three patients to whom it was administered. Reduction in signal from short T-2 components was seen in acute fractures, and increase in signal in these components was seen with new bone formation after fracture malunion. In a case of osteoporosis, bone cross-sectional area and signal level appeared reduced. Conclusion: Signal can be detected from normal and abnormal cortical bone with UTE pulse sequences, and this can be used to measure its T-1 and T2* as well as observe contrast enhancement. Difference images are of value in increasing the conspicuity of cortical bone and observing abnormalities in disease. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [41] Ultrashort TE in Cancer Imaging
    Boulougouri, Konstantina
    Messiou, Christina
    desouza, Nandita M.
    EMAGRES, 2012, 1 (01): : 97 - 102
  • [42] Functional magnetic resonance imaging with an ultrashort echo time
    Kim, Min-Ji
    Jahng, Geon-Ho
    Lee, Soo-Yeol
    Ryu, Chang-Woo
    MEDICAL PHYSICS, 2013, 40 (02)
  • [43] Comparison amongst pulse sequences for enhanced contrast to noise ratio in magnetic resonance imaging
    Amin, Naima
    Afzal, Rao Muhammad
    Yousaf, Muhammad
    Javid, Muhammad Arshad
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2017, 67 (02) : 225 - 232
  • [44] Past magnetic resonance imaging of the abdomen with turbo-spin-echo pulse sequences
    Yu, BC
    Jara, H
    Yucel, EK
    JINGSHIN PHYSICS SYMPOSIUM IN MEMORY OF PROFESSOR WOLFGANG KROLL, 1997, : 304 - 326
  • [45] Evaluation of bound and pore water in cortical bone using ultrashort-TE MRI
    Chen, Jun
    Grogan, Shawn P.
    Shao, Hongda
    D'Lima, Darryl
    Bydder, Graeme M.
    Wu, Zhihong
    Du, Jiang
    NMR IN BIOMEDICINE, 2015, 28 (12) : 1754 - 1762
  • [46] Ultrashort pulse laser interactions with cortical bone tissue for applications in orthopaedic surgery
    Ashforth, Simon A.
    Simpson, M. Cather
    Bodley, Owen
    Oosterbeek, Reece
    FRONTIERS IN ULTRAFAST OPTICS: BIOMEDICAL, SCIENTIFIC, AND INDUSTRIAL APPLICATIONS XV, 2015, 9355
  • [47] Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
    Du, Jiang
    Carl, Michael
    Bydder, Mark
    Takahashi, Atsushi
    Chung, Christine B.
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 304 - 311
  • [48] Evaluation of pulse sequences used for magnetic resonance sialography
    Sakamoto, M
    Sasano, T
    Higano, S
    Takahashi, S
    Nagasaka, T
    Yanagawa, I
    Hosogai, Y
    Tamura, H
    Iikubo, M
    Shoji, N
    DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (05) : 276 - 284
  • [49] Bone Tissue in Magnetic Resonance Imaging: Contribution of New Zero Echo Time Sequences
    Vuillemin, Valerie
    Guerini, Henri
    Thevenin, Fabrice
    Sibileau, Elodie
    Corcos, Gabriel
    Khaled, Wassef
    Zeitoun, Frederic
    Morvan, Gerard
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2023, 27 (04) : 411 - 420
  • [50] IMAGE-CONTRAST AND PULSE SEQUENCES IN URINARY-TRACT MAGNETIC-RESONANCE-IMAGING
    NEWHOUSE, JH
    UROLOGIC RADIOLOGY, 1986, 8 (03) : 120 - 126