Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences

被引:152
|
作者
Reichert, ILH
Robson, MD
Gatehouse, PD
He, TG
Chappell, KE
Holmes, J
Girgis, S
Bydder, GM [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Charing Cross Hosp, Dept Orthoped Surg, Imperial Coll, Fac Med, London W6 8RF, England
[3] Royal Brompton Hosp, Cardiac Meagnet Resonance Unit, London SW3 6NP, England
[4] Univ Oxford, Dept Cardiovasc Med, Ctr Clin Magnet Resonance Res, Oxford OX1 2JD, England
[5] MRC, Ctr Clin Sci, Imaging Sci Dept, Robert Steiner Magnet Resonance Unit, London W12 0HS, England
[6] Hammersmith Hosp, Fac Med, Imperial Coll, Dept Med, London W12 0HS, England
关键词
magnetic resonance imaging; cortical bone; ultrashort echo time; bone perfusion;
D O I
10.1016/j.mri.2005.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Normal adult cortical bone has a very short T-2 and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone in human subjects and use this signal to characterise this tissue. Subjects and Methods: Seven volunteers and 10 patients were examined using ultrashort TE pulse sequences (TE = 0.07 or 0.08 ms). Short and long inversion as well as fat suppression pulses were used as preparation pulses. Later echo images were also obtained as well as difference images produced by subtracting a later echo image from a first echo image. Saturation pulses were used for T-1 measurement and sequences with progressively increasing TEs for T-2* measurement. Intravenous gadodiamide was administered to four subjects. Results: Signal in cortical bone was detected with UTE sequences in children, normal adults and patients. This signal was usually made more obvious by subtracting a later echo image from the first provided that the signal-to-noise ratio was sufficiently high. Normal mean adult T(1)s ranged from 140 to 260 ms, and mean T-2*s ranged from 0.42 to 0.50 ms. T-1 increased significantly with age (P < .01). Increased signal was observed after contrast enhancement in the normal volunteer and the three patients to whom it was administered. Reduction in signal from short T-2 components was seen in acute fractures, and increase in signal in these components was seen with new bone formation after fracture malunion. In a case of osteoporosis, bone cross-sectional area and signal level appeared reduced. Conclusion: Signal can be detected from normal and abnormal cortical bone with UTE pulse sequences, and this can be used to measure its T-1 and T2* as well as observe contrast enhancement. Difference images are of value in increasing the conspicuity of cortical bone and observing abnormalities in disease. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [31] Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences
    Chen, Jun
    Carl, Michael
    Ma, Yajun
    Shao, Hongda
    Lu, Xing
    Chen, Bimin
    Chang, Eric Y.
    Wu, Zhihong
    Du, Jiang
    NMR IN BIOMEDICINE, 2016, 29 (10) : 1373 - 1380
  • [32] Magnetic resonance imaging with fluid attenuated pulse sequences in evaluation of craniospinal lesions
    Palmieri, A
    Muto, M
    Izzo, R
    Girardi, C
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 (02): : 223 - 234
  • [33] Comparison of Pulse Sequences of Magnetic Resonance Imaging for Optimization of Timing and Image Quality
    Amin N.
    Yousaf M.
    Javid M.A.
    Farooq A.
    Iranian Journal of Medical Physics, 2020, 17 (06) : 350 - 358
  • [34] Magnetic resonance imaging of myelin using ultrashort Echo time (UTE) pulse sequences: Phantom, specimen, volunteer and multiple sclerosis patient studies
    Sheth, Vipul
    Shao, Hongda
    Chen, Jun
    Vandenberg, Scott
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    NEUROIMAGE, 2016, 136 : 37 - 44
  • [35] Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone
    Du, Jiang
    Hamilton, Gavin
    Takahashi, Atsushi
    Bydder, Mark
    Chung, Christine B.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 1001 - 1009
  • [36] Use of double-echo ultrashort echo time magnetic resonance imaging to assess proximal femoral cortical bone changes in axial spondyloarthritis
    Li, Yitong
    Hou, Bowen
    Zhang, Yao
    Wang, Yi
    Chu, Yongqiang
    Zhang, Jing
    Li, Xiaoming
    BONE, 2025, 194
  • [37] A comprehensive set of ultrashort echo time magnetic resonance imaging biomarkers to assess cortical bone health: A feasibility study at clinical field strength
    Jacobson, Andrea M.
    Zhao, Xuandong
    Sommer, Stefan
    Sadik, Farhan
    Warden, Stuart J.
    Newman, Christopher
    Siegmund, Thomas
    Allen, Matthew R.
    Surowiec, Rachel K.
    BONE, 2024, 181
  • [38] In vivo quantitative assessment of proximal femoral cortical bone microstructure using double-echo ultrashort echo time magnetic resonance imaging
    Li, Yitong
    Hou, Bowen
    Zhang, Yao
    Wang, Yi
    Chu, Yongqiang
    Li, Xiaoming
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9323 - 9334
  • [39] Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imaging
    Wehrli, Felix W.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 390 - 409
  • [40] Ultrashort TE Imaging of Cryotherapy
    Lu, Aiming
    Daniel, Bruce L.
    Pauly, Kim Butts
    EMAGRES, 2012, 1 (03): : 539 - 550