Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences

被引:152
|
作者
Reichert, ILH
Robson, MD
Gatehouse, PD
He, TG
Chappell, KE
Holmes, J
Girgis, S
Bydder, GM [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Charing Cross Hosp, Dept Orthoped Surg, Imperial Coll, Fac Med, London W6 8RF, England
[3] Royal Brompton Hosp, Cardiac Meagnet Resonance Unit, London SW3 6NP, England
[4] Univ Oxford, Dept Cardiovasc Med, Ctr Clin Magnet Resonance Res, Oxford OX1 2JD, England
[5] MRC, Ctr Clin Sci, Imaging Sci Dept, Robert Steiner Magnet Resonance Unit, London W12 0HS, England
[6] Hammersmith Hosp, Fac Med, Imperial Coll, Dept Med, London W12 0HS, England
关键词
magnetic resonance imaging; cortical bone; ultrashort echo time; bone perfusion;
D O I
10.1016/j.mri.2005.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Normal adult cortical bone has a very short T-2 and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone in human subjects and use this signal to characterise this tissue. Subjects and Methods: Seven volunteers and 10 patients were examined using ultrashort TE pulse sequences (TE = 0.07 or 0.08 ms). Short and long inversion as well as fat suppression pulses were used as preparation pulses. Later echo images were also obtained as well as difference images produced by subtracting a later echo image from a first echo image. Saturation pulses were used for T-1 measurement and sequences with progressively increasing TEs for T-2* measurement. Intravenous gadodiamide was administered to four subjects. Results: Signal in cortical bone was detected with UTE sequences in children, normal adults and patients. This signal was usually made more obvious by subtracting a later echo image from the first provided that the signal-to-noise ratio was sufficiently high. Normal mean adult T(1)s ranged from 140 to 260 ms, and mean T-2*s ranged from 0.42 to 0.50 ms. T-1 increased significantly with age (P < .01). Increased signal was observed after contrast enhancement in the normal volunteer and the three patients to whom it was administered. Reduction in signal from short T-2 components was seen in acute fractures, and increase in signal in these components was seen with new bone formation after fracture malunion. In a case of osteoporosis, bone cross-sectional area and signal level appeared reduced. Conclusion: Signal can be detected from normal and abnormal cortical bone with UTE pulse sequences, and this can be used to measure its T-1 and T2* as well as observe contrast enhancement. Difference images are of value in increasing the conspicuity of cortical bone and observing abnormalities in disease. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [21] 3D printed phantoms mimicking cortical bone for the assessment of ultrashort echo time magnetic resonance imaging
    Rai, Robba
    Manton, David
    Jameson, Michael G.
    Josan, Sonal
    Barton, Michael B.
    Holloway, Lois C.
    Liney, Gary P.
    MEDICAL PHYSICS, 2018, 45 (02) : 758 - 766
  • [22] MAGNETIC-RESONANCE IMAGING - COMPARISON OF 4 PULSE SEQUENCES IN ASSESSING PRIMARY BONE-TUMORS
    GRAIF, M
    PENNOCK, JM
    PRINGLE, J
    SWEETNAM, DR
    JELLIFFE, AJ
    BYDDER, GM
    YOUNG, IR
    SKELETAL RADIOLOGY, 1989, 18 (06) : 439 - 444
  • [23] Impact of the Sound of Magnetic Resonance Imaging Pulse Sequences in Awake Mice
    Almeida, Joana
    Severo, Frederico
    Nunes, Daniel
    JOURNAL OF APPLIED ANIMAL WELFARE SCIENCE, 2022, 25 (01) : 75 - 88
  • [24] Assessment of cortical bone with clinical and ultrashort echo time sequences
    Du, Jiang
    Hermida, Juan C.
    Diaz, Eric
    Corbeil, Jacqueline
    Znamirowski, Richard
    D'Lima, Darryl D.
    Bydder, Graeme M.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (03) : 697 - 704
  • [25] OPTIMIZING PULSE SEQUENCES FOR MAGNETIC-RESONANCE-IMAGING OF THE MUSCULOSKELETAL SYSTEM
    RICHARDSON, ML
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1986, 24 (02) : 137 - 144
  • [26] An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance
    Jerban, Saeed
    Chang, Douglas G.
    Ma, Yajun
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [27] Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of Bone: An Update
    Ma, Ya-Jun
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Douglas
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [28] Impact of acceleration on bone depiction quality by ultrashort echo time magnetic resonance bone imaging sequences in medication-related osteonecrosis of the jaw
    Getzmann, Jonas M.
    Huber, Florian A.
    Nakhostin, Dominik
    Deininger-Czermak, Eva
    Schumann, Paul
    Finkenstaedt, Tim
    Del Grande, Filippo
    Guggenberger, Roman
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2022, 9
  • [29] Magnetic resonance imaging of short T2 relaxation components in tissue using ultrashort echo time (UTE) pulse sequences
    Bydder, M
    Znamirowski, RM
    Bydder, GM
    CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (01) : 79 - 90
  • [30] Mineralization in calcified plaque is like that of cortical bone-Further evidence from ultrashort echo time (UTE) magnetic resonance imaging of carotid plaque calcification and cortical bone
    Du, Jiang
    Peterson, Michael
    Kansal, Nikhil
    Bydder, Graeme M.
    Kahn, Andrew
    MEDICAL PHYSICS, 2013, 40 (10)