Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy

被引:55
|
作者
Lee, MC [1 ]
Jiang, SB [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
modulated electron radiation therapy (MERT); IMRT; EGS4 Monte Carlo; multileaf collimator (MLC);
D O I
10.1118/1.1328082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modulated electron radiation therapy (MERT) has been proposed as a means of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. Conventional systems for electron beam collimation are labor and time intensive in their construction and are therefore inadequate for use in the sequential delivery of multiple complex fields required by MERT. This study investigates two proposed methods of electron beam collimation: the use of existing photon multileaf collimators (MLC) in a helium atmosphere to reduce in-air electron scatter, and a MLC specifically designed for electron beam collimation. Monte Carlo simulations of a Varian Clinac 2100C were performed using the EGS4/BEAM system and dose calculations performed with the MCDOSE code. Dose penumbras from fields collimated by photon MLCs both with air and with helium at 6, 12, and 20 MeV at a range of SSDs from 70 to 90 cm were examined. Significant improvements were observed for the helium based system. Simulations were also performed on an electron specific MLC located at the level of the last scraper of a 25x25 cm(2) applicator. A number of leaf materials, thicknesses, end shapes, and widths were simulated to determine optimal construction parameters. The results demonstrated that tungsten leaves 15 mm thick and 5 mm wide with unfocused ends would provide sufficient collimation for MERT fields. A prototype electron MLC was constructed and comparisons between film measurements and simulation demonstrate the validity of the Monte Carlo model. Further simulations of dose penumbras demonstrate that such an electron MLC would provide improvements over the helium filled photon MLC at all energies, and improvements in the 90-10 penumbra of 12% to 45% at 20 MeV and 6 MeV, respectively. These improvements were also seen in isodose curves when a complex field shape was simulated. It is thus concluded that an MLC specific for electron beam collimation is required for MERT. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01612-6].
引用
收藏
页码:2708 / 2718
页数:11
相关论文
共 50 条
  • [41] Monte Carlo treatment planning for photon and electron beams
    Reynaert, N.
    van der Marck, S. C.
    Schaart, D. R.
    Van der Zee, W.
    Van Vliet-Vroegindeweij, C.
    Tomsej, M.
    Jansen, J.
    Heijmen, B.
    Coghe, M.
    De Wagter, C.
    RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (04) : 643 - 686
  • [42] MONTE-CARLO GENERATION OF ELECTRON PENCIL BEAMS
    LEVY, SI
    AYYANGAR, K
    SUNTHARALINGAM, N
    MEDICAL PHYSICS, 1983, 10 (04) : 537 - 537
  • [43] Monte Carlo simulation of small electron fields collimated by the integrated photon MLC
    Mihaljevic, Josip
    Soukup, Martin
    Dohm, Oliver
    Alber, Markus
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (03): : 829 - 843
  • [44] Investigation of Combining Modulated Electron Beams with Intensity Modulated Photons for Radiation Therapy of Breast Cases
    Eldib, A.
    Li, J.
    Jin, L.
    Ma, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3838 - 3838
  • [45] Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams
    Chow, James C. L.
    Jiang, Runqing
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3885 - 3899
  • [46] Development and verification of an electron Monte Carlo engine for applications in intraoperative radiation therapy
    Rank, Luisa
    Lysakovski, Peter
    Major, Gerald
    Ferrari, Alfredo
    Tessonnier, Thomas
    Debus, Juergen
    Mairani, Andrea
    MEDICAL PHYSICS, 2024, 51 (09) : 6348 - 6364
  • [47] Experimental and Monte-Carlo investigations of electron scattering foil systems for a clinical betatron
    Baker, CR
    Prietzel, F
    Pantos, Y
    Tandy, J
    Jennings, CS
    Mills, JA
    RADIATION PHYSICS AND CHEMISTRY, 1998, 51 (4-6) : 595 - 596
  • [48] Experimental determination of electron source parameters for accurate Monte Carlo calculation of large field electron therapy
    Huang, VW
    Seuntjens, J
    Devic, S
    Verhaegen, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 779 - 786
  • [49] Monte Carlo calculation of scattered radiation from applicators in low energy clinical electron beams
    Jabbari, Nasrollah
    Hashemi-Malayeri, Bijan
    Farajollahi, Ali Reza
    Kazemnejad, Anoshiravan
    NUKLEONIKA, 2007, 52 (03) : 97 - 103
  • [50] Monte Carlo simulation of electron cones used in electron beam therapy
    Williams, T.
    Ebert, M.
    Keall, E.
    Haskard, D.
    Australasian Physical and Engineering Sciences in Medicine, 1998, 21 (03): : 112 - 119