Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy

被引:55
|
作者
Lee, MC [1 ]
Jiang, SB [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
modulated electron radiation therapy (MERT); IMRT; EGS4 Monte Carlo; multileaf collimator (MLC);
D O I
10.1118/1.1328082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modulated electron radiation therapy (MERT) has been proposed as a means of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. Conventional systems for electron beam collimation are labor and time intensive in their construction and are therefore inadequate for use in the sequential delivery of multiple complex fields required by MERT. This study investigates two proposed methods of electron beam collimation: the use of existing photon multileaf collimators (MLC) in a helium atmosphere to reduce in-air electron scatter, and a MLC specifically designed for electron beam collimation. Monte Carlo simulations of a Varian Clinac 2100C were performed using the EGS4/BEAM system and dose calculations performed with the MCDOSE code. Dose penumbras from fields collimated by photon MLCs both with air and with helium at 6, 12, and 20 MeV at a range of SSDs from 70 to 90 cm were examined. Significant improvements were observed for the helium based system. Simulations were also performed on an electron specific MLC located at the level of the last scraper of a 25x25 cm(2) applicator. A number of leaf materials, thicknesses, end shapes, and widths were simulated to determine optimal construction parameters. The results demonstrated that tungsten leaves 15 mm thick and 5 mm wide with unfocused ends would provide sufficient collimation for MERT fields. A prototype electron MLC was constructed and comparisons between film measurements and simulation demonstrate the validity of the Monte Carlo model. Further simulations of dose penumbras demonstrate that such an electron MLC would provide improvements over the helium filled photon MLC at all energies, and improvements in the 90-10 penumbra of 12% to 45% at 20 MeV and 6 MeV, respectively. These improvements were also seen in isodose curves when a complex field shape was simulated. It is thus concluded that an MLC specific for electron beam collimation is required for MERT. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01612-6].
引用
收藏
页码:2708 / 2718
页数:11
相关论文
共 50 条
  • [31] Comparison between small radiation therapy electron beams collimated by Cerrobend and tubular applicators
    Di Venanzio, Cristina
    Marinelli, Marco
    Tonnetti, Alessia
    Verona-Rinati, Gianluca
    Bagala, Paolo
    Falco, Maria Daniela
    Guerra, Antonio Stefano
    Pimpinella, Maria
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 329 - 335
  • [32] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beams
    Hu, Ye Angela
    Song, Haijun
    Chen, Zhe
    Zhou, Sumin
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 1 - 15
  • [33] An Optimal Jaw Setting for An Electron-Specific Multileaf Collimator (eMLC) Developed for Modulated Electron Radiation Therapy (MERT)
    Eldib, A.
    Jin, L.
    Xu, Q.
    Fan, J.
    Li, J.
    Ma, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [34] Dosimetric Verification of Modulated Electron Radiation Therapy Delivered Using An Electron Specific Multileaf Collimator for Treatment of Scalp Cases
    Eldib, A.
    Jin, L.
    Martin, J.
    Li, J.
    Chibani, O.
    Mora, G.
    Galloway, T.
    Ma, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 323 - 323
  • [35] Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled electron multileaf collimator
    Jin, Lihui
    Eldib, Ahmed
    Li, Jinsheng
    Emam, Ismail
    Fan, Jiajin
    Wang, Lu
    Ma, C-M
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 177 - 186
  • [36] Magnetic-Modulated Radiation Therapy with High Energy Electron Beams
    Chen, M.
    Ma, L.
    Gu, X.
    Lu, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E372 - E373
  • [37] Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer
    Steel, Jared
    Stewart, Allan
    Satory, Philip
    MEDICAL PHYSICS, 2009, 36 (09) : 4244 - 4249
  • [38] MICRODOSIMETRY OF THERAPY ELECTRON-BEAMS - MEASUREMENTS AND MONTE-CARLO SIMULATIONS
    CHEN, J
    HAHN, K
    ROOS, H
    KELLERER, AM
    RADIATION PROTECTION DOSIMETRY, 1994, 52 (1-4) : 435 - 438
  • [39] Optimizing focused very-high-energy electron beams for radiation therapy based on Monte Carlo simulation
    An, Chaofan
    Zhang, Wei
    Dai, Zeyi
    Li, Jia
    Yang, Xiong
    Wang, Jike
    Nie, Yuancun
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [40] Theoretical and experimental investigations on electron beams
    Dosse, J.
    ZEITSCHRIFT FUR PHYSIK, 1940, 115 (9-10): : 530 - 556