Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy

被引:55
|
作者
Lee, MC [1 ]
Jiang, SB [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
modulated electron radiation therapy (MERT); IMRT; EGS4 Monte Carlo; multileaf collimator (MLC);
D O I
10.1118/1.1328082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modulated electron radiation therapy (MERT) has been proposed as a means of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. Conventional systems for electron beam collimation are labor and time intensive in their construction and are therefore inadequate for use in the sequential delivery of multiple complex fields required by MERT. This study investigates two proposed methods of electron beam collimation: the use of existing photon multileaf collimators (MLC) in a helium atmosphere to reduce in-air electron scatter, and a MLC specifically designed for electron beam collimation. Monte Carlo simulations of a Varian Clinac 2100C were performed using the EGS4/BEAM system and dose calculations performed with the MCDOSE code. Dose penumbras from fields collimated by photon MLCs both with air and with helium at 6, 12, and 20 MeV at a range of SSDs from 70 to 90 cm were examined. Significant improvements were observed for the helium based system. Simulations were also performed on an electron specific MLC located at the level of the last scraper of a 25x25 cm(2) applicator. A number of leaf materials, thicknesses, end shapes, and widths were simulated to determine optimal construction parameters. The results demonstrated that tungsten leaves 15 mm thick and 5 mm wide with unfocused ends would provide sufficient collimation for MERT fields. A prototype electron MLC was constructed and comparisons between film measurements and simulation demonstrate the validity of the Monte Carlo model. Further simulations of dose penumbras demonstrate that such an electron MLC would provide improvements over the helium filled photon MLC at all energies, and improvements in the 90-10 penumbra of 12% to 45% at 20 MeV and 6 MeV, respectively. These improvements were also seen in isodose curves when a complex field shape was simulated. It is thus concluded that an MLC specific for electron beam collimation is required for MERT. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01612-6].
引用
收藏
页码:2708 / 2718
页数:11
相关论文
共 50 条
  • [21] Experimental Validation of Peripheral Dose Distribution of Electron Beams for Eclipse Electron Monte Carlo Algorithm
    Cebe, M.
    Pacaci, P.
    Mabhouti, H.
    Codel, G.
    Sanli, E.
    Serin, E.
    Kucuk, N.
    Kucukmorkoc, E.
    Doyuran, M.
    Canoglu, D.
    Altinok, A.
    Acar, H.
    Ozkok, H. Caglar
    MEDICAL PHYSICS, 2016, 43 (06) : 3351 - 3351
  • [22] Experimental validaton of peripheral dose distribution of electron beams for eclipse electron Monte Carlo algorithm
    Acar, Hilal
    Caglar, Mustafa
    Altinok, Ayse Y.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (03) : 279 - 288
  • [23] Characterization and dosimetry of photon multileaf collimated electron beams using Gafchromic film measurements
    Mutsakanyi, Stalyn
    du Plessis, Freek
    RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [24] Dosimetry characteristics of degraded electron beams investigated by Monte Carlo calculations in a setup for intraoperative radiation therapy
    Björk, P
    Nilsson, P
    Knöös, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (02): : 239 - 256
  • [25] MONTE CARLO SIMULATION OF THE ELECTRON BEAMS PRODUCED BY A LINEAR ACCELERATOR FOR INTRA-OPERATIVE RADIATION THERAPY
    Mihailescu, D.
    Borcia, C.
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (01) : 61 - 74
  • [26] A Monte Carlo method for commissioning electron beams
    Antolak, JA
    Bieda, MS
    Hogstrom, KR
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 449 - 451
  • [27] Experimental and Monte Carlo investigations of the energy dependence of alanine/EPR dosimetry system for clinical electron and photon beams
    Zeng, GG
    McEwen, MR
    Rogers, DWO
    Klassen, NV
    MEDICAL PHYSICS, 2003, 30 (06) : 1426 - 1426
  • [28] Modulated electron beams using multi-segmented multileaf collimation
    Klein, EE
    RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 307 - 311
  • [29] Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy
    Jang, SY
    Vassiliev, ON
    Liu, HH
    Mohan, R
    Siebers, JV
    MEDICAL PHYSICS, 2006, 33 (03) : 770 - 781
  • [30] A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy
    Liu, HH
    Verhaegen, F
    Dong, L
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2283 - 2298