PETALO: Time-of-Flight PET with liquid xenon

被引:2
|
作者
Romo-Luque, C. [1 ,2 ]
机构
[1] CSIC, Inst Fis Corpuscular IFIC, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
[2] Univ Valencia, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
PET; TOF; Liquid xenon; Coincidence resolving time (CRT); SiPMs; DETECTOR;
D O I
10.1016/j.nima.2019.162397
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of the geometrical distortions of conventional detectors based on scintillating crystals. In this paper, we describe how these properties have motivated the development of a novel concept for positron emission tomography scanners with Time-Of-Flight measurement, which combines a liquid xenon scintillating volume and silicon photomultipliers as sensors. A Monte Carlo investigation has pointed out that this technology would provide an excellent intrinsic time resolution, down to 70 ps. Also, the transparency of liquid xenon to UV and blue wavelengths opens the possibility of exploiting both scintillation and Cherenkov light for a high-sensitivity positron emission tomography scanner with Time-Of-Flight capabilities. Monte Carlo simulations point to a time resolution of 30-50 ps obtained using Cherenkov light. A prototype is being built to demonstrate the high resolution in energy, time and reconstruction of spatial coordinates of this concept, using a ring of 30 cm internal diameter and a depth of 3 cm instrumented with VUV-sensitive silicon photomultipliers.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] CeBr3 for Time-of-Flight PET
    Glodo, Jarek
    Kuhn, Austin
    Higgins, William M.
    van Loef, Edgar V. D.
    Karp, Joel S.
    Moses, William W.
    Derenzo, Stephen E.
    Shah, Kanai S.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1570 - 1573
  • [22] Axial Fourier Rebinning for Time-of-Flight PET
    Li, Yusheng
    Matej, Samuel
    Metzler, Scott D.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [23] Impact of Time-of-Flight on PET Tumor Detection
    Kadrmas, Dan J.
    Casey, Michael E.
    Conti, Maurizio
    Jakoby, Bjoern W.
    Lois, Cristina
    Townsend, David W.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) : 1315 - 1323
  • [24] Analytical properties of time-of-flight PET data
    Cho, Sanghee
    Ahn, Sangtae
    Li, Quanzheng
    Leahy, Richard M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11): : 2809 - 2821
  • [25] New Consistency Equation for Time-of-Flight PET
    Defrise, Michel
    Panin, Vladimir Y.
    Casey, Michael E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 124 - 133
  • [26] Performance of the Tachyon Time-of-Flight PET Camera
    Peng, Q.
    Choong, W. -S.
    Vu, C.
    Huber, J. S.
    Janecek, M.
    Wilson, D.
    Huesman, R. H.
    Qi, Jinyi
    Zhou, Jian
    Moses, W. W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 111 - 119
  • [27] Fourier rebinning of time-of-flight PET data
    Defrise, M
    Casey, ME
    Michel, C
    Conti, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (12): : 2749 - 2763
  • [28] DETECTION PERFORMANCE ANALYSIS FOR TIME-OF-FLIGHT PET
    Cao, Nannan
    Huesman, Ronald H.
    Moses, William W.
    Qi, Jinyi
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 402 - +
  • [29] Update on latest advances in time-of-flight PET
    Surti, Suleman
    Karp, Joel S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 251 - 258
  • [30] New consistency equation for time-of-flight PET
    Defrise, Michel
    Panin, Vladimir
    Casey, Michael E.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4115 - 4120