PETALO: Time-of-Flight PET with liquid xenon

被引:2
|
作者
Romo-Luque, C. [1 ,2 ]
机构
[1] CSIC, Inst Fis Corpuscular IFIC, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
[2] Univ Valencia, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
PET; TOF; Liquid xenon; Coincidence resolving time (CRT); SiPMs; DETECTOR;
D O I
10.1016/j.nima.2019.162397
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of the geometrical distortions of conventional detectors based on scintillating crystals. In this paper, we describe how these properties have motivated the development of a novel concept for positron emission tomography scanners with Time-Of-Flight measurement, which combines a liquid xenon scintillating volume and silicon photomultipliers as sensors. A Monte Carlo investigation has pointed out that this technology would provide an excellent intrinsic time resolution, down to 70 ps. Also, the transparency of liquid xenon to UV and blue wavelengths opens the possibility of exploiting both scintillation and Cherenkov light for a high-sensitivity positron emission tomography scanner with Time-Of-Flight capabilities. Monte Carlo simulations point to a time resolution of 30-50 ps obtained using Cherenkov light. A prototype is being built to demonstrate the high resolution in energy, time and reconstruction of spatial coordinates of this concept, using a ring of 30 cm internal diameter and a depth of 3 cm instrumented with VUV-sensitive silicon photomultipliers.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Towards time-of-flight PET with a semiconductor detector
    Arino-Estrada, Gerard
    Mitchell, Gregory S.
    Kwon, Sun Il
    Du, Junwei
    Kim, Hadong
    Cirignano, Leonard J.
    Shah, Kanai S.
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (04):
  • [32] Optimal Rebinning of Time-of-Flight PET Data
    Ahn, Sangtae
    Cho, Sanghee
    Li, Quanzheng
    Lin, Yanguang
    Leahy, Richard M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (10) : 1808 - 1818
  • [33] Physics and technology of time-of-flight PET detectors
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (09):
  • [34] Development of Tachyon Time-of-Flight PET Cameras
    Peng, Qiyu
    Moses, William
    Zhang, Xuezhu
    Qi, Jinyi
    Zhao, Zhixiang
    Huang, Qiu
    Zhu, Yicheng
    Sui, Tengjie
    Yang, Mingming
    Xu, Jianfeng
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [35] Additional Gains with Time-of-Flight PET at High Counting Rates: Lessons Learned from Early Time-of-Flight PET Systems
    Mullani, Nizar A.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1491 - 1493
  • [36] Liquid xenon in nuclear medicine: state-of-the-art and the PETALO approach
    Ferrario, P.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [37] Focus on time-of-flight PET: the benefits of improved time resolution
    Conti, Maurizio
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) : 1147 - 1157
  • [38] Dark Count Resilient Time Estimators for Time-of-Flight PET
    Lemaire, William
    Therrien, Audrey C.
    Pratte, Jean-Francois
    Fontaine, Rejean
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (01) : 24 - 29
  • [39] Time-of-flight PET time calibration using data consistency
    Defrise, Michel
    Rezaei, Ahmadreza
    Nuyts, Johan
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (10):
  • [40] Focus on time-of-flight PET: the benefits of improved time resolution
    Maurizio Conti
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 1147 - 1157