PETALO: Time-of-Flight PET with liquid xenon

被引:2
|
作者
Romo-Luque, C. [1 ,2 ]
机构
[1] CSIC, Inst Fis Corpuscular IFIC, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
[2] Univ Valencia, Calle Catedratico Jose Beltran 2, Valencia 46980, Spain
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
PET; TOF; Liquid xenon; Coincidence resolving time (CRT); SiPMs; DETECTOR;
D O I
10.1016/j.nima.2019.162397
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of the geometrical distortions of conventional detectors based on scintillating crystals. In this paper, we describe how these properties have motivated the development of a novel concept for positron emission tomography scanners with Time-Of-Flight measurement, which combines a liquid xenon scintillating volume and silicon photomultipliers as sensors. A Monte Carlo investigation has pointed out that this technology would provide an excellent intrinsic time resolution, down to 70 ps. Also, the transparency of liquid xenon to UV and blue wavelengths opens the possibility of exploiting both scintillation and Cherenkov light for a high-sensitivity positron emission tomography scanner with Time-Of-Flight capabilities. Monte Carlo simulations point to a time resolution of 30-50 ps obtained using Cherenkov light. A prototype is being built to demonstrate the high resolution in energy, time and reconstruction of spatial coordinates of this concept, using a ring of 30 cm internal diameter and a depth of 3 cm instrumented with VUV-sensitive silicon photomultipliers.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Using time-of-flight information for PET, PET/CT and PET/MRI reconstruction
    Nuyts, Johan
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (01):
  • [42] Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?
    Giovanni Lucignani
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 969 - 971
  • [43] Recent advances and future advances in time-of-flight PET
    Moses, William W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 919 - 924
  • [44] Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Rezaei, Ahmadreza
    Nuyts, Johan
    Defrise, Michel
    Bal, Girish
    Michel, Christian
    Conti, Maurizio
    Watson, Charles
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2375 - 2382
  • [45] Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?
    Lucignani, Giovanni
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (08) : 969 - 971
  • [46] PET Performance of the GEMINI TF: A Time-of-flight PET/CT Scanner
    Muzic, Raymond F., Jr.
    Kolthammer, Jeffrey A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1940 - 1944
  • [47] LROC analysis of human detection performance in PET and time-of-flight PET
    Gifford, HC
    Wells, RG
    King, MA
    MEDICAL IMAGING 1999: IMAGE PERCEPTION AND PERFORMANCE, 1999, 3663 : 187 - 198
  • [48] Recent Advances and Future Advances in Time-of-Flight PET
    Moses, William W.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2009, 1204 : 119 - 125
  • [49] On the way to the 10 ps time-of-flight PET challenge
    Lecoq, P.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (08):
  • [50] IMAGE IMPROVEMENT AND DESIGN OPTIMIZATION OF THE TIME-OF-FLIGHT PET
    WONG, WH
    MULLANI, NA
    PHILIPPE, EA
    HARTZ, R
    GOULD, KL
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (01) : 52 - 60