Geant4 simulation of a filtered X-ray source for radiation damage studies

被引:15
|
作者
Guthoff, M. [1 ]
Brovchenko, O. [1 ]
de Boer, W. [1 ]
Dierlamm, A. [1 ]
Mueller, T. [1 ]
Ritter, A. [1 ]
Schmanau, M. [1 ]
Simonis, H. -J. [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Expt Kernphys, D-76128 Karlsruhe, Germany
关键词
X-ray; Energy spectrum; Silicon drift diode; Geant4;
D O I
10.1016/j.nima.2012.01.029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [31] Fine structure of angular distribution of x-ray transition radiation from multilayered radiator in Geant4
    Savchenko, A. A.
    Tishchenko, A. A.
    Sergeeva, D. Yu.
    Belyaev, N.
    Cherry, M.
    Dachs, F.
    Doronin, S.
    Filippov, K.
    Fusco, P.
    Gargano, F.
    Konovalov, S.
    Loparco, F.
    Mascagna, V.
    Mazziotta, M. N.
    Nechaeva, S.
    Ponomarenko, D.
    Romaniouk, A.
    Schioppa, E. J.
    Smirnov, S.
    Smirnov, Y.
    Soldani, M.
    Spinelli, P.
    Strikhanov, M. N.
    Teterin, P.
    Tikhomirov, V. O.
    Vorobev, K.
    Zhukov, K.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06)
  • [32] Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4
    Nasseri, Mohammad M.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (03) : 795 - 798
  • [33] A Geant4 simulation of X-ray emission for three-dimensional proton imaging of microscopic samples
    Michelet, Claire
    Li, Zhuxin
    Jalenques, H.
    Incerti, Sebastien
    Barberet, Philippe
    Deves, Guillaume
    Delville, Marie-Helene
    Seznec, Herve
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 94 : 85 - 93
  • [34] Geant4 simulation of neutron displacement damage in SiC
    Guo, D.-X., 1600, Atomic Energy Press (47):
  • [35] SOLPEX X-ray polarimeter detector luminescence background calculated using Geant4 simulation software
    Gorgolewski, Aleksander
    Barylak, Jaromir
    Steslicki, Marek
    Szaforz, Zaneta
    Bakala, Jaroslaw
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2016, 2016, 10031
  • [36] The Research of Polarized Energy Dispersive X-Ray Fluorescence for Measurement Trace Cadmium by Geant4 Simulation
    Ouyang Zhou-xuan
    Ma Ying-jie
    Li Dou-dou
    Liu Yi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (04) : 1064 - 1069
  • [37] MCNPX and GEANT4 simulation of γ-ray polymeric shields
    Tabbakh, F.
    PRAMANA-JOURNAL OF PHYSICS, 2016, 86 (04): : 939 - 944
  • [38] Geant4 Simulation of Scatter Radiation Removal: Comparison and Validation of Anti-scatter Grid and Air Gap for X-ray Mammography
    Alyassin, Abdalmajeid M.
    Aljarrah, Ali H.
    Ababneh, Zaid Q.
    Ababneh, Anas M.
    Alyassin, Noor A.
    JORDAN JOURNAL OF PHYSICS, 2024, 17 (01): : 17 - 33
  • [39] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92
  • [40] New module for channeling radiation simulation in Geant4
    Savchenko, A. A.
    Wagner, W.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12)