Geant4 simulation of a filtered X-ray source for radiation damage studies

被引:15
|
作者
Guthoff, M. [1 ]
Brovchenko, O. [1 ]
de Boer, W. [1 ]
Dierlamm, A. [1 ]
Mueller, T. [1 ]
Ritter, A. [1 ]
Schmanau, M. [1 ]
Simonis, H. -J. [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Expt Kernphys, D-76128 Karlsruhe, Germany
关键词
X-ray; Energy spectrum; Silicon drift diode; Geant4;
D O I
10.1016/j.nima.2012.01.029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [41] Geant4 Based Simulation of Radiation Dosimetry in CUDA
    Murakami, K.
    Henderson, N.
    Amako, K.
    Asai, M.
    Aso, T.
    Dotti, A.
    Kimura, A.
    Gerritsen, M.
    Kurashige, H.
    Perl, J.
    Sasaki, T.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [42] Geant4 simulations of a wide-angle x-ray focusing telescope
    Zhao, Donghua
    Zhang, Chen
    Yuan, Weimin
    Zhang, Shuangnan
    Willingale, Richard
    Ling, Zhixing
    EXPERIMENTAL ASTRONOMY, 2017, 43 (03) : 267 - 283
  • [43] MCNPX and GEANT4 simulation of γ-ray polymeric shields
    F TABBAKH
    Pramana, 2016, 86 : 939 - 944
  • [44] Validation of a Geant4 model of the X-ray fluorescence microprobe at the Australian Synchrotron
    Dimmock, Matthew Richard
    de Jonge, Martin Daly
    Howard, Daryl Lloyd
    James, Simon Alexander
    Kirkham, Robin
    Paganin, David Maurice
    Paterson, David John
    Ruben, Gary
    Ryan, Chris Gregory
    Brown, Jeremy Michael Cooney
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 354 - 365
  • [45] Implement X-ray refraction effect in Geant4 for phase contrast imaging
    Wang, Zhentian
    Huang, Zhifeng
    Zhang, Li
    Chen, Zhiqiang
    Kang, Kejun
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2395 - 2398
  • [46] X-ray differential phase-contrast imaging simulations with Geant4
    Brombal, L.
    Arfelli, F.
    Brun, F.
    Longo, F.
    Poles, N.
    Rigon, L.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (04)
  • [47] GEANT4 validation for X-ray treatment of wooden cultural heritage artefacts
    Morgunov, V
    Hybler, P.
    Zachar, M.
    APPLIED RADIATION AND ISOTOPES, 2021, 169
  • [48] Geant4 simulations of a wide-angle x-ray focusing telescope
    Donghua Zhao
    Chen Zhang
    Weimin Yuan
    Shuangnan Zhang
    Richard Willingale
    Zhixing Ling
    Experimental Astronomy, 2017, 43 : 267 - 283
  • [49] Geant4 simulations of STIX Caliste-SO detector's response to solar X-ray radiation
    Barylak, Jaromir
    Barylak, Aleksandra
    Mrozek, Tomasz
    Steslicki, Marek
    Podgorski, Piotr
    Netzel, Henryka
    SOLAR AND STELLAR FLARES AND THEIR EFFECTS ON PLANETS, 2016, 11 (S320): : 439 - 441
  • [50] Background radiation studies at LHCb using Geant4
    Daquino, G. G.
    Corti, G.
    Folger, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2907 - 2915