Geant4 simulation of a filtered X-ray source for radiation damage studies

被引:15
|
作者
Guthoff, M. [1 ]
Brovchenko, O. [1 ]
de Boer, W. [1 ]
Dierlamm, A. [1 ]
Mueller, T. [1 ]
Ritter, A. [1 ]
Schmanau, M. [1 ]
Simonis, H. -J. [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Expt Kernphys, D-76128 Karlsruhe, Germany
关键词
X-ray; Energy spectrum; Silicon drift diode; Geant4;
D O I
10.1016/j.nima.2012.01.029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [21] Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation
    Wadeson, Nicola
    Morton, Edward
    Lionheart, William
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [22] ZnO nanowires in polycarbonate membrane as a high resolution X-ray detector (a Geant4 simulation)
    Taheri, Ali
    Saramad, Shahyar
    Setayeshi, Saeed
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 716 : 15 - 22
  • [23] Geant4 Simulation for LHC Radiation Monitoring
    Glaser, M.
    Guatelli, S.
    Mascialino, B.
    Moll, M.
    Pia, M. G.
    Ravotti, F.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1470 - 1472
  • [24] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Abbasian Motlagh Mehdi
    Rastegarzadeh Gohar
    Instruments and Experimental Techniques, 2023, 66 : 451 - 455
  • [25] Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study
    Mohammad Mehdi Nasseri
    Pramana, 2019, 92
  • [26] GEANT4 simulation study of over-response phenomenon of fiber x-ray sensor
    张彬
    谢天赐
    秦壮
    李昊鹏
    李松
    赵文辉
    陈子印
    徐军
    Elfed Lewis
    孙伟民
    Chinese Physics B, 2021, 30 (04) : 732 - 738
  • [27] X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4
    Kapadia, A.
    Samei, E.
    Harrawood, B.
    Sahbaee, P.
    Chawla, A.
    Tan, Z.
    Brady, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3642 - 3643
  • [28] Geant4 simulations of soft proton scattering in X-ray optics
    Fioretti, Valentina
    Mineo, Teresa
    Bulgarelli, Andrea
    Dondero, Paolo
    Ivanchenko, Vladimir
    Lei, Fan
    Lotti, Simone
    Macculi, Claudio
    Mantero, Alfonso
    EXPERIMENTAL ASTRONOMY, 2017, 44 (03) : 413 - 435
  • [29] Comparing the output of measured and GEANT4 simulated X-ray tubes
    Kirkpatrick, Molly
    Hood, Sean
    Guatelli, Susanna
    Van Haarlem, Yves
    RADIATION PHYSICS AND CHEMISTRY, 2024, 220
  • [30] Simulating Modulated X-ray calibration Sources for future X-ray missions, using GEANT4
    de Vries, C. P.
    Fioretti, V.
    den Herder, J. W.
    Schyns, E.
    Pinto, S. D.
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699