A Geant4 simulation of X-ray emission for three-dimensional proton imaging of microscopic samples

被引:1
|
作者
Michelet, Claire [1 ]
Li, Zhuxin [1 ]
Jalenques, H. [1 ]
Incerti, Sebastien [1 ]
Barberet, Philippe [1 ]
Deves, Guillaume [1 ]
Delville, Marie-Helene [2 ]
Seznec, Herve [1 ]
机构
[1] Univ Bordeaux, UMR5797, CENBG, CNRS, F-33170 Gradignan, France
[2] Univ Bordeaux, UMR5026, ICMCB, CNRS, 87 Ave Dr A Schweitzer, F-33608 Pessac, France
关键词
Geant4; simulation; Proton computed tomography; PIXE tomography; Caenorhabditis elegans; PIXE-TOMOGRAPHY; SOFTWARE PACKAGE; RECONSTRUCTION; CELLS;
D O I
10.1016/j.ejmp.2021.12.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Proton computed micmtomography is a technique that reveals the inner content of microscopic samples. The density distribution of the material (in g.cm(-3)) is obtained from proton transmission tomography (STIM: Scanning Transmission Ion Microscopy) and the element content from X-ray emission tomography (PIXE: Particle Induced X-ray Emission). A precise quantification of chemical elements is difficult for thick samples, because of the variations of X-ray production cross-sections and of X-ray absorption. Both phenomena are at the origin of an attenuation of the measured X-ray spectra, which leads to an underestimation of the element content. Our aim is to quantify the accuracy of a specific correction method that we designed for thick samples. Methods: In this study, we describe how the 3D variations in the mass density were taken into account in the reconstruction code, in order to quantify the correction according to the position of the proton beam and the position and aperture angle of the X-ray detector. Moreover, we assess the accuracy of the reconstructed densities using Geant4 simulations on numerical phantoms, used as references. Results: The correction process was successfully applied and led, for the largest regions of interest (little affected by partial volume effects), to an accuracy <= 4% for phosphorus (compared to about 40% discrepancy without correction). Conclusion: This study demonstrates the accuracy of the correction method implemented in the tomographic reconstruction code for thick samples. It also points out some advantages offered by Geant4 simulations: i) they produce projection data that are totally independent of the inversion method used for the image reconstruction; ii) one or more physical processes (X-ray absorption, proton energy loss) can be artificially turned off, in order to precisely quantify the effect of the different phenomena involved in the attenuation of X-ray spectra.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 50 条
  • [1] A Geant4 simulation for three-dimensional proton imaging of microscopic samples
    Michelet, Claire
    Li, Zhuxin
    Yang, Wen
    Incerti, Sebastien
    Desbarats, Pascal
    Giovannelli, Jean-Francois
    Barberet, Philippe
    Delville, Marie-Helene
    Gordillo, Nuria
    Deves, Guillaume
    Seznec, Herve
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 172 - 180
  • [2] Geant4 simulation of the response of phosphor screens for X-ray imaging
    Pistrui-Maximean, S. A.
    Freud, N.
    Letang, J. M.
    Koch, A.
    Munier, B.
    Walenta, A. H.
    Montarou, G.
    Babot, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 196 - 199
  • [3] Accuracy of three-dimensional proton imaging of an inertial confinement fusion target assessed by Geant4 simulation
    Li, Zhuxin
    Incerti, Sebastien
    Beasley, Daniel
    Shen, Hao
    Wang, Shimei
    Sezneo, Herve
    Michelet, Claire
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 536 : 38 - 44
  • [4] Geant4 simulations of soft proton scattering in X-ray optics
    Fioretti, Valentina
    Mineo, Teresa
    Bulgarelli, Andrea
    Dondero, Paolo
    Ivanchenko, Vladimir
    Lei, Fan
    Lotti, Simone
    Macculi, Claudio
    Mantero, Alfonso
    EXPERIMENTAL ASTRONOMY, 2017, 44 (03) : 413 - 435
  • [5] A GEANT4 based simulation for pixelated X-ray hybrid detectors
    Marinho, F.
    Akiba, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 50 - 51
  • [6] Fast simulation of x-ray transition radiation in the GEANT4 toolkit
    Grichine, VM
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 117 - 122
  • [7] GEANT4 simulation and spectrum restoration of a pixelated X-ray detector
    Tykhonov, Andrii
    Winkler, Alexander
    Smoliar, Volodymyr
    JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [8] X-ray tracing using Geant4
    Buis, E. J.
    Vacanti, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 599 (2-3): : 260 - 263
  • [9] GEANT4 simulation of X-ray transition radiation at small angles
    Grichine, V. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [10] Evaluation of the X-ray distribution of a syringe-needle type proton-induced X-ray source by Geant4 simulation
    Hu, Y.
    Fukuda, H.
    Oguri, Y.
    X-RAY SPECTROMETRY, 2017, 46 (05) : 356 - 360