A Geant4 simulation of X-ray emission for three-dimensional proton imaging of microscopic samples

被引:1
|
作者
Michelet, Claire [1 ]
Li, Zhuxin [1 ]
Jalenques, H. [1 ]
Incerti, Sebastien [1 ]
Barberet, Philippe [1 ]
Deves, Guillaume [1 ]
Delville, Marie-Helene [2 ]
Seznec, Herve [1 ]
机构
[1] Univ Bordeaux, UMR5797, CENBG, CNRS, F-33170 Gradignan, France
[2] Univ Bordeaux, UMR5026, ICMCB, CNRS, 87 Ave Dr A Schweitzer, F-33608 Pessac, France
关键词
Geant4; simulation; Proton computed tomography; PIXE tomography; Caenorhabditis elegans; PIXE-TOMOGRAPHY; SOFTWARE PACKAGE; RECONSTRUCTION; CELLS;
D O I
10.1016/j.ejmp.2021.12.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Proton computed micmtomography is a technique that reveals the inner content of microscopic samples. The density distribution of the material (in g.cm(-3)) is obtained from proton transmission tomography (STIM: Scanning Transmission Ion Microscopy) and the element content from X-ray emission tomography (PIXE: Particle Induced X-ray Emission). A precise quantification of chemical elements is difficult for thick samples, because of the variations of X-ray production cross-sections and of X-ray absorption. Both phenomena are at the origin of an attenuation of the measured X-ray spectra, which leads to an underestimation of the element content. Our aim is to quantify the accuracy of a specific correction method that we designed for thick samples. Methods: In this study, we describe how the 3D variations in the mass density were taken into account in the reconstruction code, in order to quantify the correction according to the position of the proton beam and the position and aperture angle of the X-ray detector. Moreover, we assess the accuracy of the reconstructed densities using Geant4 simulations on numerical phantoms, used as references. Results: The correction process was successfully applied and led, for the largest regions of interest (little affected by partial volume effects), to an accuracy <= 4% for phosphorus (compared to about 40% discrepancy without correction). Conclusion: This study demonstrates the accuracy of the correction method implemented in the tomographic reconstruction code for thick samples. It also points out some advantages offered by Geant4 simulations: i) they produce projection data that are totally independent of the inversion method used for the image reconstruction; ii) one or more physical processes (X-ray absorption, proton energy loss) can be artificially turned off, in order to precisely quantify the effect of the different phenomena involved in the attenuation of X-ray spectra.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 50 条
  • [21] Geant4 Simulation of the Effect of Cherenkov Radiation Cone Transformation in the X-ray Region
    I. A. Kishin
    V. I. Dronik
    A. S. Kubankin
    R. M. Nazhmudinov
    V. S. Sotnikova
    Bulletin of the Lebedev Physics Institute, 2022, 49 : 322 - 328
  • [22] Geant4 Simulation of the Effect of Cherenkov Radiation Cone Transformation in the X-ray Region
    Kishin, I. A.
    Dronik, V. I.
    Kubankin, A. S.
    Nazhmudinov, R. M.
    Sotnikova, V. S.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2022, 49 (10) : 322 - 328
  • [23] GEANT4 simulation in proton medical imaging: A transport models comparison
    Silva, R. C. L.
    Denyak, V.
    Hoff, G.
    Paschuk, S. A.
    Schelin, H. R.
    Setti, J. A. P.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [24] Geant4 simulation of proton-induced single event upset in three-dimensional die-stacked SRAM device
    Ye, Bing
    Mo, Li-Hua
    Liu, Tao
    Luo, Jie
    Li, Dong-Qing
    Zhao, Pei-Xiong
    Cai, Chang
    He, Ze
    Sun, You-Mei
    Hou, Ming-Dong
    Liu, Jie
    CHINESE PHYSICS B, 2020, 29 (02)
  • [25] Geant4 simulation of proton-induced single event upset in three-dimensional die-stacked SRAM device
    叶兵
    莫莉华
    刘涛
    罗捷
    李东青
    赵培雄
    蔡畅
    贺泽
    孙友梅
    侯明东
    刘杰
    Chinese Physics B, 2020, (02) : 432 - 438
  • [26] Processing of three-dimensional microscopic X-ray fluorescence data
    Vekemans, B., 1600, Royal Society of Chemistry (19):
  • [27] Processing of three-dimensional microscopic X-ray fluorescence data
    Vekemans, B
    Vincze, L
    Brenker, FE
    Adams, F
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (10) : 1302 - 1308
  • [28] Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations
    Depauw, Nicolas
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2407 - 2421
  • [29] Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study
    Nasseri, Mohammad Mehdi
    PRAMANA-JOURNAL OF PHYSICS, 2019, 92 (04):
  • [30] Three-dimensional X-ray Imaging for Security Screening
    Paul Evans
    Security Journal, 2005, 18 (1) : 19 - 28