Effect of print angulation on the accuracy and precision of 3D-printed orthodontic retainers

被引:17
|
作者
Williams, Allison [1 ]
Bencharit, Sompop [2 ]
Yang, Il-Hyung [3 ,4 ,5 ]
Stilianoudakis, Spiro Christos [6 ]
Carrico, Caroline K. [6 ,7 ]
Tufekci, Eser [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Dent, Dept Orthodont, 520 N 12th St,POB 980566, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Sch Dent, Dept Gen Practice, Richmond, VA 23298 USA
[3] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[5] Virginia Commonwealth Univ, Sch Dent, Richmond, VA 23298 USA
[6] Virginia Commonwealth Univ, Sch Dent, Dept Biostat, Richmond, VA 23298 USA
[7] Virginia Commonwealth Univ, Sch Dent, Dept Dent Publ Hlth & Policy, Richmond, VA 23298 USA
关键词
TRUENESS;
D O I
10.1016/j.ajodo.2021.01.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The study aimed to (1) compare the accuracy and precision of 3- dimensional (3D) printed retainers at various angulations and (2) evaluate the effect of angulation on printing time and the amount of resin consumed. Methods: Using a stereolithography 3D printer, 60 clear retainers were printed at 5 angulations (n = 12, each): 15 degrees, 30 degrees, 45 degrees, 60 degrees, and 90 degrees. Samples for each group were randomly printed in a batch of 6 retainers at all print angulations as print 1 and print 2 cycles. Digital images of the original and printed samples were superimposed. Discrepancies on 8 landmarks were measured by 2 independent examiners, and 0.25 mm was set as the clinically acceptable threshold to determine the accuracy of the retainers. Results: Deviations ranged from 0.074 mm to 0.225 mm from the reference retainer at the cusp tips and incisal edges at all angulations, falling within the threshold of clinical acceptance. However, smooth surface measurements with deviations up to 0.480 mm were deemed clinically not acceptable. Three-dimensional printing at 15 degrees was estimated to be the most time-efficient, whereas 3D printing at 45 degrees was shown to be the most cost-effective setting. Conclusions: Three-dimensional printed retainers, using a stereolithography printer, were found to be accurate within 0.25 mm at all print angulations at the cusp tips and incisal edges compared with the digital reference file. Smooth facial surfaces did not meet clinical acceptability. Print angulations were shown to affect the cost and amount of resin used.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [31] The Effect of Bonding Surface Design on Shear Bond Strength of 3D-Printed Orthodontic Attachments
    Noorollahian, Saeed
    Zarei, Zahra
    Sadeghalbanaei, Leila
    Pakzamir, Khashayar
    INTERNATIONAL JOURNAL OF DENTISTRY, 2023, 2023
  • [32] Effect of the Height of a 3D-Printed Model on the Force Transmission and Thickness of Thermoformed Orthodontic Aligners
    Ghoraba, Omar
    Bourauel, Christoph
    Aldesoki, Mostafa
    Singer, Lamia
    Ismail, Ahmed M.
    Elattar, Hanaa
    Alhotan, Abdulaziz
    Elshazly, Tarek M.
    MATERIALS, 2024, 17 (12)
  • [33] Accuracy and precision of 3D-printed implant surgical guides with different implant systems: An in vitro study
    Yeung, Matthew
    Abdulmajeed, Aous
    Carrico, Caroline K.
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06): : 821 - 828
  • [34] Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
    Wang, Yipeng
    Wang, Peiqi
    Xiang, Xiang
    Xu, Hui
    Tang, Yuting
    Zhou, Yumeng
    Bai, Ding
    Xue, Chaoran
    BMC ORAL HEALTH, 2022, 22 (01)
  • [35] Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
    Yipeng Wang
    Peiqi Wang
    Xiang Xiang
    Hui Xu
    Yuting Tang
    Yumeng Zhou
    Ding Bai
    Chaoran Xue
    BMC Oral Health, 22
  • [36] The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models
    Hartley, Olan
    Shanbhag, Tanvi
    Smith, Derek
    Grimm, Antonio
    Salameh, Ziad
    Tadakamadla, Santosh K.
    Alifui-Segbaya, Frank
    Ahmed, Khaled E.
    POLYMERS, 2022, 14 (24)
  • [37] Effect of Printing Direction on the Accuracy of 3D-Printed Dentures Using Stereolithography Technology
    Hada, Tamaki
    Kanazawa, Manabu
    Iwaki, Maiko
    Arakida, Toshio
    Soeda, Yumika
    Katheng, Awutsadaporn
    Otake, Ryosuke
    Minakuchi, Shunsuke
    MATERIALS, 2020, 13 (15) : 1 - 12
  • [38] Effect of different storage conditions on dimensional accuracy of 3D-printed dental models
    Alshaibani, Raghdah M.
    Fan, Yuwei
    Giordano II, Russell
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [39] Comparative evaluation of the accuracy of 3D-printed denture teeth
    Alalawi, Haidar
    Al-Qarni, Faisal D.
    Gad, Mohammed M.
    SAUDI DENTAL JOURNAL, 2023, 35 (04) : 365 - 371
  • [40] Accuracy of a simplified 3D-printed implant surgical guide
    Kim, Taehun
    Lee, Sangwook
    Kim, Guk Bae
    Hong, Dayeong
    Kwon, Jinhee
    Park, Jae-Woo
    Kim, Namkug
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 195 - +