Effect of print angulation on the accuracy and precision of 3D-printed orthodontic retainers

被引:17
|
作者
Williams, Allison [1 ]
Bencharit, Sompop [2 ]
Yang, Il-Hyung [3 ,4 ,5 ]
Stilianoudakis, Spiro Christos [6 ]
Carrico, Caroline K. [6 ,7 ]
Tufekci, Eser [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Dent, Dept Orthodont, 520 N 12th St,POB 980566, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Sch Dent, Dept Gen Practice, Richmond, VA 23298 USA
[3] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[5] Virginia Commonwealth Univ, Sch Dent, Richmond, VA 23298 USA
[6] Virginia Commonwealth Univ, Sch Dent, Dept Biostat, Richmond, VA 23298 USA
[7] Virginia Commonwealth Univ, Sch Dent, Dept Dent Publ Hlth & Policy, Richmond, VA 23298 USA
关键词
TRUENESS;
D O I
10.1016/j.ajodo.2021.01.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The study aimed to (1) compare the accuracy and precision of 3- dimensional (3D) printed retainers at various angulations and (2) evaluate the effect of angulation on printing time and the amount of resin consumed. Methods: Using a stereolithography 3D printer, 60 clear retainers were printed at 5 angulations (n = 12, each): 15 degrees, 30 degrees, 45 degrees, 60 degrees, and 90 degrees. Samples for each group were randomly printed in a batch of 6 retainers at all print angulations as print 1 and print 2 cycles. Digital images of the original and printed samples were superimposed. Discrepancies on 8 landmarks were measured by 2 independent examiners, and 0.25 mm was set as the clinically acceptable threshold to determine the accuracy of the retainers. Results: Deviations ranged from 0.074 mm to 0.225 mm from the reference retainer at the cusp tips and incisal edges at all angulations, falling within the threshold of clinical acceptance. However, smooth surface measurements with deviations up to 0.480 mm were deemed clinically not acceptable. Three-dimensional printing at 15 degrees was estimated to be the most time-efficient, whereas 3D printing at 45 degrees was shown to be the most cost-effective setting. Conclusions: Three-dimensional printed retainers, using a stereolithography printer, were found to be accurate within 0.25 mm at all print angulations at the cusp tips and incisal edges compared with the digital reference file. Smooth facial surfaces did not meet clinical acceptability. Print angulations were shown to affect the cost and amount of resin used.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [21] Comparison of 3-dimensional printing technologies on the precision, trueness, and accuracy of printed retainers
    Naeem, Owais A.
    Bencharit, Sompop
    Yang, Il-Hyung
    Stilianoudakis, Spiro Christos
    Carrico, Caroline
    Tufekci, Eser
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (04) : 582 - 591
  • [22] Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models
    Favero, Christian S.
    English, Jeryl D.
    Cozad, Benjamin E.
    Wirthlin, John O.
    Short, Megan M.
    Kasper, F. Kurtis
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (04) : 557 - 565
  • [23] Colour stability of 3D-printed resin orthodontic brackets
    Haynie, Allison S.
    English, Jeryl D.
    Paravina, Rade D.
    Moon, Audrey
    Hanigan, James
    Abu Al Tamn, Mustafa A.
    Kasper, F. Kurtis
    JOURNAL OF ORTHODONTICS, 2021, 48 (03) : 241 - 249
  • [24] Transfer accuracy of 3D-printed trays for indirect bonding o orthodontic brackets: A clinical study
    Bachour, Petra C.
    Klabunde, Robert
    Grunheid, Thorsten
    ANGLE ORTHODONTIST, 2022, 92 (03) : 372 - 379
  • [25] 3D-printed swab with cover for precision diagnosis
    Fan Huang
    Kewei Song
    Yue Jiang
    Kayo Hirose
    Shinjiro Umezu
    Journal of Materials Science: Materials in Medicine, 2022, 33
  • [26] 3D-printed swab with cover for precision diagnosis
    Huang, Fan
    Song, Kewei
    Jiang, Yue
    Hirose, Kayo
    Umezu, Shinjiro
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2022, 33 (01)
  • [27] 3D-Printed Linear Positioner with Micrometer Accuracy
    Kuo, Yin-Yen
    Cheng, Chiao-Hua
    Hung, Shao-Kang
    2016 THE 3RD INTERNATIONAL CONFERENCE ON MECHATRONICS AND MECHANICAL ENGINEERING (ICMME 2016), 2017, 95
  • [28] Accuracy assessment of 3D-printed tooth replicas
    Sokolowski, Armin Andreas
    Sokolowski, Alwin Alan
    Kammerhofer, Julian
    Madreiter-Sokolowski, Corina Theresia
    Payer, Michael
    Koller, Martin
    Jakse, Norbert
    Wegscheider, Walther Alfred
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 321 - 329
  • [29] The Accuracy of 3D-Printed Fixed Dental Restorations
    Alammar, Amirah
    Att, Wael
    Beuer, Florian
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [30] Effect of Material and Pad Abrasion on Shear Bond Strength of 3D-Printed Orthodontic Brackets
    Hanson, Megan S.
    Ontiveros, Joe C.
    English, Jeryl D.
    Wirthlin, John O.
    Cozad, Benjamin E.
    Harrington, Daniel A.
    Kasper, F. Kurtis
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2023, 26 : 171 - 179