Validation of SIMIND Monte Carlo Simulation Software for Modelling a Siemens Symbia T SPECT Scintillation Camera

被引:5
|
作者
Ejeh, John E. [1 ,2 ]
van Staden, Johan A. [1 ]
du Raan, Hanlie [1 ]
机构
[1] Univ Free State, Dept Med Phys, Bloemfontein, South Africa
[2] Univ Coll Hosp Ibadan, Dept Nucl Med, Ibadan, Nigeria
关键词
Computer simulation; Code validation; SIMIND; Septal penetration fraction; Monte Carlo; SEGMENTATION; SCATTER;
D O I
10.1007/978-981-10-9035-6_106
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of Monte Carlo (MC) simulations in nuclear medicine is on the rise due to its usefulness in modelling many physical phenomena which are difficult or impossible to measure. To use MC for gamma camera image simulations, it is important to validate the simulated data with the measured data to ensure that what is simulated is a true representation of the physical system being modelled. Therefore, in this study, the SIMIND MC code for modelling a Siemens Symbia T dual head SPECT/CT gamma camera fitted with high energy all-purpose collimators (HEAP) was validated. The validation was done by acquiring and simulating certain NEMA stipulated performance measurements for I-131. These measured and simulated performance data were processed and the results compared. The FWHM and FWTM for the gamma camera for measured and simulated system spatial resolution were 14.4, 29.7 mm versus 13.9, 25.9 mm. System sensitivity performance measurements and simulation produced results of 49 cps/MBq and 48 cps/MBq respectively. The corresponding measured and simulated values for the septal penetration were 3.8 and 4.2%. From this study it is evident that the SIMIND MC Code can be used with confidence to mimic I-131 studies acquired with a Siemens Symbia T SPECT/CT gamma camera fitted with HEAP collimators.
引用
收藏
页码:573 / 576
页数:4
相关论文
共 50 条
  • [41] Modelling and commissioning validation of eclipse conical cone collimator for stereotactic radiosurgery using Monte Carlo simulation
    Shende, Ravindra
    Dhoble, S. J.
    Saroj, Dinesh
    Gupta, Gourav
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [42] Scintillation event localization in hemi-ellipsoid detector for SPECT, a simulation study using Geant4 Monte-Carlo
    Soysal, H. R.
    Dey, J.
    Donahue, W. P.
    Matthews, K. L.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [43] Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function
    Song, X
    Segars, WP
    Du, Y
    Tsui, BMW
    Frey, EC
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08): : 1791 - 1804
  • [44] Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study
    Malelizadeh, Etesam
    Rajabi, Hossein
    Fiorina, Elisa
    Kalantari, Faraz
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2021, 29 (02): : 86 - 92
  • [45] Assessment of a Monte-Carlo simulation of SPECT recordings from a new-generation heart-centric semiconductor camera: from point sources to human images
    Imbert, Laetitia
    Galbrun, Ernest
    Odille, Freddy
    Poussier, Sylvain
    Noel, Alain
    Wolf, Didier
    Karcher, Gilles
    Marie, Pierre-Yves
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1007 - 1018
  • [46] Assessment of a Monte-Carlo simulation of SPECT recordings from a new- generation heart-centric semiconductor camera: from punctual sources to human images
    Imbert, L.
    Galbrun, E.
    Odille, F.
    Poussier, S.
    Noel, A.
    Wolf, D.
    Karcher, G.
    Marie, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S613 - S613
  • [47] WATER EQUIVALENCE OF VARIOUS 3D PRINTED MATERIALS FOR PROTON THERAPY - MONTE CARLO SIMULATION, TREATMENT PLANNING MODELLING AND VALIDATION BY MEASUREMENTS
    Wochnik, Agnieszka
    Swakon, Jan
    Olko, Pawel
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 409 - 412
  • [48] Dynamic 99mTc-MAG3 renography: images for quality control obtained by combining pharmacokinetic modelling, an anthropomorphic computer phantom and Monte Carlo simulated scintillation camera imaging
    Brolin, Gustav
    Gleisner, Katarina Sjogreen
    Ljungberg, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (10): : 3145 - 3161
  • [49] Modelling and validation of a 6 MV compact linear accelerator via Monte Carlo simulation using Geant4 Application for Tomographic Emission (GATE)
    Limbaco, Maynard E.
    Toledo, Franklin U.
    Tondo, Renna Mae, V
    Nawang, Salasa A.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (02):
  • [50] Generalised storage-yield-reliability modelling: Independent validation of the Vogel-Stedinger (V-S) model using a Monte Carlo simulation approach
    Adeloye, Adebayo J.
    Pal, Sudip
    O'Neill, Michelagh
    JOURNAL OF HYDROLOGY, 2010, 388 (3-4) : 234 - 240