Validation of SIMIND Monte Carlo Simulation Software for Modelling a Siemens Symbia T SPECT Scintillation Camera

被引:5
|
作者
Ejeh, John E. [1 ,2 ]
van Staden, Johan A. [1 ]
du Raan, Hanlie [1 ]
机构
[1] Univ Free State, Dept Med Phys, Bloemfontein, South Africa
[2] Univ Coll Hosp Ibadan, Dept Nucl Med, Ibadan, Nigeria
关键词
Computer simulation; Code validation; SIMIND; Septal penetration fraction; Monte Carlo; SEGMENTATION; SCATTER;
D O I
10.1007/978-981-10-9035-6_106
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of Monte Carlo (MC) simulations in nuclear medicine is on the rise due to its usefulness in modelling many physical phenomena which are difficult or impossible to measure. To use MC for gamma camera image simulations, it is important to validate the simulated data with the measured data to ensure that what is simulated is a true representation of the physical system being modelled. Therefore, in this study, the SIMIND MC code for modelling a Siemens Symbia T dual head SPECT/CT gamma camera fitted with high energy all-purpose collimators (HEAP) was validated. The validation was done by acquiring and simulating certain NEMA stipulated performance measurements for I-131. These measured and simulated performance data were processed and the results compared. The FWHM and FWTM for the gamma camera for measured and simulated system spatial resolution were 14.4, 29.7 mm versus 13.9, 25.9 mm. System sensitivity performance measurements and simulation produced results of 49 cps/MBq and 48 cps/MBq respectively. The corresponding measured and simulated values for the septal penetration were 3.8 and 4.2%. From this study it is evident that the SIMIND MC Code can be used with confidence to mimic I-131 studies acquired with a Siemens Symbia T SPECT/CT gamma camera fitted with HEAP collimators.
引用
收藏
页码:573 / 576
页数:4
相关论文
共 50 条
  • [21] Performance estimation of high resolution SPECT for the human brain by Monte Carlo simulation of scintillation lights
    Hirano, Y.
    Zeniya, T.
    Watabe, H.
    Iida, H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3353 - 3356
  • [22] Development and validation of a Monte Carlo simulation of a gamma camera using MCNP.
    O'Connor, MK
    Monville, ME
    Nonneman, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 97P - 98P
  • [23] A Monte Carlo simulation of coincidence detection and imaging of gamma-ray cascades with a scintillation camera
    Pahlka, R. Benton
    Kappadath, S. Cheenu
    Mawlawi, Osama R.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):
  • [24] DEVELOPMENT AND VALIDATION OF A MONTE-CARLO SIMULATION OF PHOTON TRANSPORT IN AN ANGER CAMERA
    DEVRIES, DJ
    MOORE, SC
    ZIMMERMAN, RE
    MUELLER, SP
    FRIEDLAND, B
    LANZA, RC
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) : 430 - 438
  • [25] Modelling of high-energy contamination in SPECT imaging using Monte Carlo simulation
    Cot, A
    Jané, E
    Sempau, J
    Falcón, C
    Bullich, S
    Pavia, J
    Calviño, F
    Ros, D
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4028 - 4031
  • [26] CIS: A GUI-BASED SOFTWARE SYSTEM FOR MONTE CARLO SIMULATION OF COMPTON CAMERA
    Lee, Se Hyung
    Seo, Hee
    Park, Jin Hyung
    Park, Sung Ho
    Lee, Jae Sung
    Lee, Ju Hahn
    Lee, Chun Sik
    Kim, Chan Hyeong
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 55 - 60
  • [27] Validation and optimization studies of small animal SPECT using GATE Monte Carlo simulation
    Sadremomtaz, Alireza
    Telikani, Zeinab
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 915 : 94 - 101
  • [28] Towards a standardization of the description and validation of Monte Carlo simulation codes in SPECT and PET.
    Buvat, I
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 207P - 207P
  • [29] Denoising of Scintillation Camera Images Using a Deep Convolutional Neural Network: A Monte Carlo Simulation Approach
    Minarik, David
    Enqvist, Olof
    Tragardh, Elin
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (02) : 298 - 303
  • [30] Monte Carlo simulation of scintillation photons for the design of a high-resolution SPECT detector dedicated to human brain
    Hirano, Yoshiyuki
    Zeniya, Tsutomu
    Iida, Hidehiro
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (03) : 214 - 221