Validation of SIMIND Monte Carlo Simulation Software for Modelling a Siemens Symbia T SPECT Scintillation Camera

被引:5
|
作者
Ejeh, John E. [1 ,2 ]
van Staden, Johan A. [1 ]
du Raan, Hanlie [1 ]
机构
[1] Univ Free State, Dept Med Phys, Bloemfontein, South Africa
[2] Univ Coll Hosp Ibadan, Dept Nucl Med, Ibadan, Nigeria
关键词
Computer simulation; Code validation; SIMIND; Septal penetration fraction; Monte Carlo; SEGMENTATION; SCATTER;
D O I
10.1007/978-981-10-9035-6_106
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of Monte Carlo (MC) simulations in nuclear medicine is on the rise due to its usefulness in modelling many physical phenomena which are difficult or impossible to measure. To use MC for gamma camera image simulations, it is important to validate the simulated data with the measured data to ensure that what is simulated is a true representation of the physical system being modelled. Therefore, in this study, the SIMIND MC code for modelling a Siemens Symbia T dual head SPECT/CT gamma camera fitted with high energy all-purpose collimators (HEAP) was validated. The validation was done by acquiring and simulating certain NEMA stipulated performance measurements for I-131. These measured and simulated performance data were processed and the results compared. The FWHM and FWTM for the gamma camera for measured and simulated system spatial resolution were 14.4, 29.7 mm versus 13.9, 25.9 mm. System sensitivity performance measurements and simulation produced results of 49 cps/MBq and 48 cps/MBq respectively. The corresponding measured and simulated values for the septal penetration were 3.8 and 4.2%. From this study it is evident that the SIMIND MC Code can be used with confidence to mimic I-131 studies acquired with a Siemens Symbia T SPECT/CT gamma camera fitted with HEAP collimators.
引用
收藏
页码:573 / 576
页数:4
相关论文
共 50 条
  • [11] Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    HELIYON, 2021, 7 (06)
  • [12] Monte Carlo Simulation of Intrinsic Count Rate Performance for Scintillation Gamma Camera
    Mowlavi, A. A.
    de Denaro, M.
    Fornasier, M. R.
    Binesh, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 209 - 211
  • [13] Capabilities of the Monte Carlo Simulation Codes for Modeling of a Small Animal SPECT Camera
    Sadremomtaz A.
    Telikani Z.
    Nuclear Medicine and Molecular Imaging, 2018, 52 (4) : 303 - 310
  • [14] Monte Carlo simulation of intrinsic count rate performance of a scintillation camera for diagnostic images
    Mowlavi, AA
    de Denaro, M
    Fornasier, MR
    Binesh, A
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (03) : 390 - 395
  • [15] Validation of Tc-99m and Lu-177 quantification parameters for a SIMIND Monte Carlo modelled gamma camera
    Kamrani, S.
    Sheikhzadeh, P.
    Kamali-Asl, A.
    Rahmim, A.
    Akhavanallaf, A.
    Aghamiri, S.
    Darvishi, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S695 - S696
  • [16] Quantitative validation of Monte Carlo SPECT simulation: application to a Mediso AnyScan GATE simulation
    Pells, Sophia
    Cullen, David M.
    Deidda, Daniel
    Denis-Bacelar, Ana M.
    Fenwick, Andrew
    Ferreira, Kelley M.
    Hamilton, David
    Heetun, Warda
    Julyan, Peter
    Needham, George
    Pietras, Ben
    Price, Emlyn
    Scuffham, James
    Tipping, Jill
    Robinson, Andrew P.
    EJNMMI PHYSICS, 2023, 10 (01)
  • [17] Quantitative validation of Monte Carlo SPECT simulation: application to a Mediso AnyScan GATE simulation
    Sophia Pells
    David M. Cullen
    Daniel Deidda
    Ana M. Denis-Bacelar
    Andrew Fenwick
    Kelley M. Ferreira
    David Hamilton
    Warda Heetun
    Peter Julyan
    George Needham
    Ben Pietras
    Emlyn Price
    James Scuffham
    Jill Tipping
    Andrew P. Robinson
    EJNMMI Physics, 10
  • [18] Development and Validation of a Monte Carlo Simulation Tool for Multi-Pinhole SPECT
    Greta S. P. Mok
    Yong Du
    Yuchuan Wang
    Eric C. Frey
    Benjamin M. W. Tsui
    Molecular Imaging and Biology, 2010, 12 : 295 - 304
  • [19] Development and Validation of a Monte Carlo Simulation Tool for Multi-Pinhole SPECT
    Mok, Greta S. P.
    Du, Yong
    Wang, Yuchuan
    Frey, Eric C.
    Tsui, Benjamin M. W.
    MOLECULAR IMAGING AND BIOLOGY, 2010, 12 (03) : 295 - 304
  • [20] Performance estimation of high resolution SPECT for the human brain by Monte Carlo simulation of scintillation lights
    Hirano, Y.
    Zeniya, T.
    Watabe, H.
    Iida, H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3602 - 3605