摘要
The use of Monte Carlo (MC) simulations in nuclear medicine is on the rise due to its usefulness in modelling many physical phenomena which are difficult or impossible to measure. To use MC for gamma camera image simulations, it is important to validate the simulated data with the measured data to ensure that what is simulated is a true representation of the physical system being modelled. Therefore, in this study, the SIMIND MC code for modelling a Siemens Symbia T dual head SPECT/CT gamma camera fitted with high energy all-purpose collimators (HEAP) was validated. The validation was done by acquiring and simulating certain NEMA stipulated performance measurements for I-131. These measured and simulated performance data were processed and the results compared. The FWHM and FWTM for the gamma camera for measured and simulated system spatial resolution were 14.4, 29.7 mm versus 13.9, 25.9 mm. System sensitivity performance measurements and simulation produced results of 49 cps/MBq and 48 cps/MBq respectively. The corresponding measured and simulated values for the septal penetration were 3.8 and 4.2%. From this study it is evident that the SIMIND MC Code can be used with confidence to mimic I-131 studies acquired with a Siemens Symbia T SPECT/CT gamma camera fitted with HEAP collimators.
引用
收藏
页码:573 / 576
页数:4
相关论文
共 50 条
  • [1] Monte Carlo simulations of a scintillation camera using GATE: validation and application modelling
    Staelens, S
    Strul, D
    Santin, G
    Vandenberghe, S
    Koole, M
    D'Asseler, Y
    Lemahieu, I
    van de Walle, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (18): : 3021 - 3042
  • [2] Monte Carlo simulation of a SPECT system: GATE, MCNPX or SIMIND? (a comparative study)
    Taheri, A.
    Heidary, S.
    Shahrabi, H.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [3] Monte Carlo simulation of a SPECT system: GATE, MCNPX or SIMIND? (a comparative study)
    Taheri, A.
    Heidary, S.
    Shahrabi, H.
    Journal of Instrumentation, 2017, 12 (12):
  • [4] Modelling of energy-dependent spectral resolution for SPECT Monte Carlo simulations using SIMIND
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    HELIYON, 2021, 7 (02)
  • [5] Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging
    Lazaro, D
    Buvat, I
    Loudos, G
    Strul, D
    Santin, G
    Giokaris, N
    Donnarieix, D
    Maigne, L
    Spanoudaki, V
    Styliaris, S
    Staelens, S
    Breton, V
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02): : 271 - 285
  • [6] Simulation of Intrinsic Resolution of Scintillation Camera in Monte Carlo Environment
    Dong, Xianling
    Saad, Wira Hidayat Mohd
    Adnan, Wan Azizun Wan
    Hashim, Suhairul
    Hassan, Nor Pai'za Mohd.
    Nordin, Abd Jalil
    Saripan, M. Iqbal
    2013 IEEE INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING APPLICATIONS (IEEE ICSIPA 2013), 2013, : 11 - 14
  • [7] A MONTE-CARLO PROGRAM FOR THE SIMULATION OF SCINTILLATION CAMERA CHARACTERISTICS
    LJUNGBERG, M
    STRAND, SE
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 29 (04) : 257 - 272
  • [8] Validation of the Monte Carlo Simulation of a Siemens Biograph mCT PET
    Vazquez Canelas, L.
    Quintana Arnes, B.
    Montes Fuentes, C.
    Gutierrez Palmero, M. J.
    Tamayo Alonso, P.
    Blasco, J. M.
    BASIC CONCEPTS IN NUCLEAR PHYSICS: THEORY, EXPERIMENTS AND APPLICATIONS, 2016, 182 : 227 - 231
  • [9] Fast Monte Carlo simulation of Siemens IQ-SPECT with SMARTZOOM collimator
    Du, Yong
    Bhattacharya, Manojeet
    Frey, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [10] A Monte Carlo Simulation Study of Optimization for Collimator in a Pixelated SPECT Camera
    Telikani, Zeinab
    Sadremomtaz, Alireza
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (01) : 163 - 170