Effect of Doubly Fed Induction Generator on Transient Stability Analysis under Fault Conditions

被引:8
|
作者
Soued, S. [1 ]
Ramadan, H. S. [1 ,2 ]
Becherif, M. [1 ]
机构
[1] Bourgogne Franche Comte Univ UTBM, CNRS, FR 3539, Femto ST,Dept Energy,FCLab,UMR 6174, Belfort, France
[2] Zagazig Univ, Fac Engn, Elect Power & Machines Dept, Zagazig 44519, Egypt
关键词
Doubly-fed induction generator; Fault types; Transient stability; Wind Energy;
D O I
10.1016/j.egypro.2019.04.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind is one of the most widely used non-conventional sources of energy. The majority of wind farms use a variable speed Wind Turbines Generator (WTGs) equipped with Doubly-Fed Induction Generator (DFIG) due to their advantages over other WTGs. The analysis of Wind Energy (WE) dynamics with the DFIG - Wind Turbines (WTs) has become an interesting research issue during transient faults. This paper investigates the effects of the different faults on transient stability. The analysis is performed on a 6-bus test system during transient faults and loss of excitation in synchronous generators. The stator-flux oriented vector control approach used for both stator and Rotor Side Converter (RSC) is proposed to mitigate DFIGs impacts on the system stability. The dynamic performance of DFIG variable speed WT under faults conditions are simulated using Neplan (R) program, considering different disturbance natures. (C) 2019 The Authors. Published by Elsevier Ltd
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [1] Doubly fed induction generator model for transient stability analysis
    Ledesma, P
    Usaola, J
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) : 388 - 397
  • [2] Transient Responses of the Doubly-Fed Induction Generator Wind Turbine under Grid Fault Conditions
    Phan, T. T.
    Nguyen, V. L.
    Hossain, M. J.
    To, A. N.
    Tran, H. T.
    Phan, T. N.
    2016 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND APPLICATIONS (ACOMP), 2016, : 97 - 104
  • [3] Investigation of Doubly Fed Induction Generator Behavior Under Symmetrical and Asymmetrical Fault Conditions
    Tamvada, Karthik
    Umashankar, S.
    Sanjeevikumar, P.
    ADVANCES IN SYSTEMS, CONTROL AND AUTOMATION, 2018, 442 : 347 - 353
  • [4] Control and stability analysis of a doubly fed induction generator
    Bouaouiche, Toufik
    Machmoum, Mohamed
    2006 12TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2006, : 327 - +
  • [5] Transient Analysis of Brushless Doubly-Fed Induction Generator
    Liu, Guangjun
    Wang, Xuefan
    Xiong, Fei
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [6] FAULT DIAGNOSIS FOR A DOUBLY FED INDUCTION GENERATOR
    Abdelmalek, Samir
    Barazane, Linda
    Larabi, Abdelkader
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2016, 61 (02): : 159 - 163
  • [7] Virtual Transient Flux Linkage Control of Doubly Fed Induction Generator Under Symmetrical Grid Fault
    Lu, Shixin
    Liu, Guorong
    Hu, Shiyang
    Yang, Xiaoliang
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 274 - 283
  • [8] Transient Voltage Stability Analysis of Doubly-fed Induction Generator Based on Singularity Principle
    Zhang, Jianxin
    Yang, Huanhuan
    Qiu, Jian
    Xv, Guanghu
    Gao, Qin
    Jiang, Tuo
    Li, Peng
    Chen, Jvnquan
    Li, Jiqi
    Ke, Deping
    2023 3rd International Conference on Energy Engineering and Power Systems, EEPS 2023, 2023, : 63 - 68
  • [9] Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions
    Zergaw, Kidist Berhane
    Tuka, Milkias Berhanu
    JORDAN JOURNAL OF ELECTRICAL ENGINEERING, 2023, 9 (03): : 338 - 356
  • [10] A New Simplified Doubly Fed Induction Generator Model for Transient Stability Studies
    Kim, Dong-Joon
    Moon, Young-Hwan
    Nam, Hae-Kon
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (03) : 1030 - 1042