Effect of Doubly Fed Induction Generator on Transient Stability Analysis under Fault Conditions

被引:8
|
作者
Soued, S. [1 ]
Ramadan, H. S. [1 ,2 ]
Becherif, M. [1 ]
机构
[1] Bourgogne Franche Comte Univ UTBM, CNRS, FR 3539, Femto ST,Dept Energy,FCLab,UMR 6174, Belfort, France
[2] Zagazig Univ, Fac Engn, Elect Power & Machines Dept, Zagazig 44519, Egypt
关键词
Doubly-fed induction generator; Fault types; Transient stability; Wind Energy;
D O I
10.1016/j.egypro.2019.04.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind is one of the most widely used non-conventional sources of energy. The majority of wind farms use a variable speed Wind Turbines Generator (WTGs) equipped with Doubly-Fed Induction Generator (DFIG) due to their advantages over other WTGs. The analysis of Wind Energy (WE) dynamics with the DFIG - Wind Turbines (WTs) has become an interesting research issue during transient faults. This paper investigates the effects of the different faults on transient stability. The analysis is performed on a 6-bus test system during transient faults and loss of excitation in synchronous generators. The stator-flux oriented vector control approach used for both stator and Rotor Side Converter (RSC) is proposed to mitigate DFIGs impacts on the system stability. The dynamic performance of DFIG variable speed WT under faults conditions are simulated using Neplan (R) program, considering different disturbance natures. (C) 2019 The Authors. Published by Elsevier Ltd
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [21] Correlation among the transient characteristics of doubly fed induction generators under grid fault
    Ouyang, Jinxin
    Xiong, Xiaofu
    Qi, Xiaoguang
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (01)
  • [22] Small Signal Stability Analysis of Doubly Fed Induction Generator including SDBR
    Shawon, Mohammad Hasanuzzaman
    Al Durra, Ahmed
    Caruana, Cedric
    Muyeen, S. M.
    2012 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2012), 2012,
  • [23] Frequency Coupling Characteristic Modeling and Stability Analysis of Doubly Fed Induction Generator
    Xu, Yunyang
    Nian, Heng
    Wang, Tao
    Chen, Liang
    Zheng, Taiying
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (03) : 1475 - 1486
  • [24] Dynamic phasor modeling of the doubly-fed induction generator under unbalanced conditions
    Demiray, T.
    Milano, F.
    Andersson, G.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1049 - +
  • [25] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135
  • [26] Novel Fault Ride-Through Configuration and Transient Management Scheme for Doubly Fed Induction Generator
    Huang, Po-Hsu
    El Moursi, Mohamed Shawky
    Xiao, Weidong
    Kirtley, James L., Jr.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (01) : 86 - 94
  • [27] Modeling and Fault Characteristics Analysis of Doubly Fed Induction Generator Incorporating Crowbar Protection
    Ali, Arshad
    Larik, Nauman Ali
    Tahir, Muhammad Faizan
    Abbassi, Rabeh
    Jerbi, Houssem
    Mehmood, Kashif
    JOURNAL OF ELECTRICAL SYSTEMS, 2020, 16 (03) : 393 - 410
  • [28] Improving Analysis of Low Voltage Ride Through Capability in Turbines Connected to The Brushless Doubly Fed Induction Generator (BDFIG) under Fault Conditions
    Alizadeh, Maryam
    Ghazi, Reza
    Haghani, Ehsan Erfani
    Rad, Mohammad Esmaeili
    34TH INTERNATIONAL POWER SYSTEM CONFERENCE (PSC2019), 2019, : 655 - 661
  • [29] Study on Improving LVRT Ability of Doubly-fed Induction Generator under Asymmetric Fault
    Yao Shu-jun
    Ma Lu-yao
    Wang Yan
    Yang Jing
    Liu Long-hui
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [30] Improved Demagnetization Control of a Doubly-Fed Induction Generator Under Balanced Grid Fault
    Zhou, Linyuan
    Liu, Jinjun
    Zhou, Sizhan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (12) : 6695 - 6705