Effect of Doubly Fed Induction Generator on Transient Stability Analysis under Fault Conditions

被引:8
|
作者
Soued, S. [1 ]
Ramadan, H. S. [1 ,2 ]
Becherif, M. [1 ]
机构
[1] Bourgogne Franche Comte Univ UTBM, CNRS, FR 3539, Femto ST,Dept Energy,FCLab,UMR 6174, Belfort, France
[2] Zagazig Univ, Fac Engn, Elect Power & Machines Dept, Zagazig 44519, Egypt
关键词
Doubly-fed induction generator; Fault types; Transient stability; Wind Energy;
D O I
10.1016/j.egypro.2019.04.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind is one of the most widely used non-conventional sources of energy. The majority of wind farms use a variable speed Wind Turbines Generator (WTGs) equipped with Doubly-Fed Induction Generator (DFIG) due to their advantages over other WTGs. The analysis of Wind Energy (WE) dynamics with the DFIG - Wind Turbines (WTs) has become an interesting research issue during transient faults. This paper investigates the effects of the different faults on transient stability. The analysis is performed on a 6-bus test system during transient faults and loss of excitation in synchronous generators. The stator-flux oriented vector control approach used for both stator and Rotor Side Converter (RSC) is proposed to mitigate DFIGs impacts on the system stability. The dynamic performance of DFIG variable speed WT under faults conditions are simulated using Neplan (R) program, considering different disturbance natures. (C) 2019 The Authors. Published by Elsevier Ltd
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [31] Dynamic response of doubly fed induction generator variable speed wind turbine under fault
    El-Sattar, A. A.
    Saad, N. H.
    El-Dein, M. Z. Shams
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (07) : 1240 - 1246
  • [32] Transient Stability Enhancement of Doubly Fed Induction Machine-Based Wind Generator by Bridge-Type Fault Current Limiter
    Rashid, Gilmanur
    Ali, Mohd Hasan
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [33] Transient Stability Enhancement of Doubly Fed Induction Machine-Based Wind Generator by Bridge-Type Fault Current Limiter
    Rashid, Gilmanur
    Ali, Mohd Hasan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (03) : 939 - 947
  • [34] Harmonic Analysis of Doubly Fed Induction Generator based Utility Interactive Wind Turbine Systems during Fault Conditions
    Yasa, Yusuf
    Sozer, Yilmaz
    Mese, Erkan
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 2270 - 2276
  • [35] Active and reactive power distribution under steady-state and transient conditions in doubly-fed induction generator (DFIG)
    Nesci, S.
    Gomez, J. C.
    Morcos, M. M.
    Sanchez, L.
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [36] Effective protection for doubly fed induction generator-based wind turbines under three-phase fault conditions
    J. J. Justo
    F. Mwasilu
    J. W. Jung
    Electrical Engineering, 2018, 100 : 543 - 556
  • [37] Effective protection for doubly fed induction generator-based wind turbines under three-phase fault conditions
    Justo, J. J.
    Mwasilu, F.
    Jung, J. W.
    ELECTRICAL ENGINEERING, 2018, 100 (02) : 543 - 556
  • [38] Current sensor fault detection and reconfiguration for a Doubly Fed Induction Generator
    Rothenhagen, Kai
    Fuchs, Friedrich W.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 2732 - 2738
  • [39] The Research on the Characteristic of Fault Current of Doubly-Fed Induction Generator
    Ao-Yang, Han
    Zhe, Zhang
    Xiang-Gen, Yin
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 947 - 950
  • [40] Voltage sensor fault detection and reconfiguration for a doubly fed induction generator
    Rothenhagen, Kai
    Thomsen, Soenke
    Fuchs, Friedrich W.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS & DRIVES, 2007, : 256 - 261