Effect of Doubly Fed Induction Generator on Transient Stability Analysis under Fault Conditions

被引:8
|
作者
Soued, S. [1 ]
Ramadan, H. S. [1 ,2 ]
Becherif, M. [1 ]
机构
[1] Bourgogne Franche Comte Univ UTBM, CNRS, FR 3539, Femto ST,Dept Energy,FCLab,UMR 6174, Belfort, France
[2] Zagazig Univ, Fac Engn, Elect Power & Machines Dept, Zagazig 44519, Egypt
来源
EMERGING AND RENEWABLE ENERGY: GENERATION AND AUTOMATION | 2019年 / 162卷
关键词
Doubly-fed induction generator; Fault types; Transient stability; Wind Energy;
D O I
10.1016/j.egypro.2019.04.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind is one of the most widely used non-conventional sources of energy. The majority of wind farms use a variable speed Wind Turbines Generator (WTGs) equipped with Doubly-Fed Induction Generator (DFIG) due to their advantages over other WTGs. The analysis of Wind Energy (WE) dynamics with the DFIG - Wind Turbines (WTs) has become an interesting research issue during transient faults. This paper investigates the effects of the different faults on transient stability. The analysis is performed on a 6-bus test system during transient faults and loss of excitation in synchronous generators. The stator-flux oriented vector control approach used for both stator and Rotor Side Converter (RSC) is proposed to mitigate DFIGs impacts on the system stability. The dynamic performance of DFIG variable speed WT under faults conditions are simulated using Neplan (R) program, considering different disturbance natures. (C) 2019 The Authors. Published by Elsevier Ltd
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [41] Transient states of wind power plant with doubly fed induction generator
    Lerch, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (06): : 118 - 124
  • [42] Open switch fault diagnosis for a doubly-fed induction generator
    Sae-Kok, W.
    Grant, D. M.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 368 - +
  • [43] Transient Behavior of Doubly Fed Induction Generator during Voltage Recovery
    Hu, Sheng
    Zou, Xudong
    Kang, Yong
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 3180 - 3186
  • [44] A new approach for transient stability improvement of a grid-connected doubly fed induction generator–based wind generator
    Hossain M.E.
    Wind Engineering, 2017, 41 (04) : 245 - 259
  • [45] Additive and multiplicative fault diagnosis for a doubly-fed induction generator
    Boulkroune, Boulaid
    Galvez-Carrillo, Manuel
    Kinnaert, Michel
    2011 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), 2011, : 1302 - 1308
  • [46] An Analytical Model for Detailed Transient Fault Analysis of Doubly-Fed Induction Machines
    Maurer, Frederic
    Noland, Jonas Kristiansen
    2020 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), VOL 1, 2020, : 1287 - 1293
  • [47] Design and Analysis of Brushless Doubly Fed Induction Generator
    Resmi, R.
    Agoram, C. Arun
    Adithya, P.
    Vanitha, V.
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 604 - 610
  • [48] Transient analysis and crowbar design of doubly-fed induction generator with crowbar protection under grid voltage dips
    Xiong, Wei
    Zou, Xudong
    Huang, Qingjun
    Liang, Zongze
    Chen, Jianqing
    Kang, Yong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 117 - 125
  • [49] TRANSIENT STATE ANALYSIS OF A DOUBLY-FED INDUCTION GENERATOR UNDER 3-PHASE SHORT-CIRCUIT
    VICATOS, MS
    TEGOPOULOS, JA
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1991, 6 (01) : 62 - 68
  • [50] Enhancement of a reduced order doubly fed induction generator model for wind farm transient stability analyses
    Dosoglu, Mehmet Kenan
    Basa Arsoy, Amen
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2016, 24 (04) : 2124 - 2134