Investigation of Doubly Fed Induction Generator Behavior Under Symmetrical and Asymmetrical Fault Conditions

被引:0
|
作者
Tamvada, Karthik [1 ]
Umashankar, S. [1 ]
Sanjeevikumar, P. [2 ]
机构
[1] VIT Univ, Sch Elect Engn, Vellore, Tamil Nadu, India
[2] Univ Johannesburg, Dept Elect & Elect Engn, Johannesburg, South Africa
关键词
DFIG; Fault analysis; Modeling; Simulation; Electric grid; ENERGY-CONVERSION SYSTEM; GRID INTEGRATION; WIND POWER; CONTROLLER; DFIG; RIDE;
D O I
10.1007/978-981-10-4762-6_33
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical energy is required to run everyday appliances. It is generated by from conventional energy sources, which are exhaustible; therefore, the importance of non-conventional energy sources is increasing by the hour. Wind energy as an energy source is non-polluting and does not pose any threat to nature. For utilizing this source of energy, it is imperative to find suitable ways to harness it. This paper involves simulation of a DFIG for wind energy applications its investigation under different network fault conditions, both symmetrical and asymmetrical. The simulation is carried out with the aid of Simulink toolbox in MATLAB.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 50 条
  • [1] Hardware-based hybrid scheme to improve the fault ride through capability of doubly fed induction generator under symmetrical and asymmetrical fault
    Uddin, Waqar
    Zeb, Kamran
    Tanoli, Ayesha
    Haider, Aun
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (01) : 200 - 206
  • [2] Performance Improvement of Grid-Integrated Doubly Fed Induction Generator under Asymmetrical and Symmetrical Faults
    Soomro, Mansoor
    Memon, Zubair Ahmed
    Baloch, Mazhar Hussain
    Mirjat, Nayyar Hussain
    Kumar, Laveet
    Tran, Quynh T.
    Zizzo, Gaetano
    ENERGIES, 2023, 16 (08)
  • [3] Effect of Doubly Fed Induction Generator on Transient Stability Analysis under Fault Conditions
    Soued, S.
    Ramadan, H. S.
    Becherif, M.
    EMERGING AND RENEWABLE ENERGY: GENERATION AND AUTOMATION, 2019, 162 : 315 - 324
  • [4] Improved fault ride through strategy for doubly fed induction generator based wind turbines under both symmetrical and asymmetrical grid faults
    Mohammadi, Jafar
    Afsharnia, Saeed
    Vaez-Zadeh, Sadegh
    Farhangi, Shahrokh
    IET RENEWABLE POWER GENERATION, 2016, 10 (08) : 1114 - 1122
  • [5] Control of Doubly Fed Induction Generator under Symmetrical Voltage dips
    Lopez, Jesus
    Sanchis, Pablo
    Gubia, Eugenio
    Ursua, Alfredo
    Marroyo, Luis
    Roboam, Xavier
    2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5, 2008, : 1574 - 1580
  • [6] Behavior of Doubly-Fed Induction Generator Under Nearby Wind Plant Fault
    Aluko, Olumide
    Smith, Travis M.
    Tolbert, Leon M.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [7] Virtual Transient Flux Linkage Control of Doubly Fed Induction Generator Under Symmetrical Grid Fault
    Lu, Shixin
    Liu, Guorong
    Hu, Shiyang
    Yang, Xiaoliang
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 274 - 283
  • [8] Dynamic behavior of the excitation circuit of a doubly-fed induction generator under a symmetrical voltage drop
    Ouyang, Jinxin
    Xiong, Xiaofu
    RENEWABLE ENERGY, 2014, 71 : 629 - 638
  • [9] FAULT DIAGNOSIS FOR A DOUBLY FED INDUCTION GENERATOR
    Abdelmalek, Samir
    Barazane, Linda
    Larabi, Abdelkader
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2016, 61 (02): : 159 - 163
  • [10] An Adaptive Series-Dynamic-Resistor-Based Protection Scheme for Brushless Doubly- Fed Induction Generator Under Asymmetrical Fault Conditions
    Gholizadeh, Mahyar
    Ghasemkhani, Amir
    Tohidi, Sajjad
    Oraee, Ashknaz
    Oraee, Hashem
    Najafi, Ehsan
    IEEE ACCESS, 2024, 12 : 11330 - 11339