Investigation of Doubly Fed Induction Generator Behavior Under Symmetrical and Asymmetrical Fault Conditions

被引:0
|
作者
Tamvada, Karthik [1 ]
Umashankar, S. [1 ]
Sanjeevikumar, P. [2 ]
机构
[1] VIT Univ, Sch Elect Engn, Vellore, Tamil Nadu, India
[2] Univ Johannesburg, Dept Elect & Elect Engn, Johannesburg, South Africa
关键词
DFIG; Fault analysis; Modeling; Simulation; Electric grid; ENERGY-CONVERSION SYSTEM; GRID INTEGRATION; WIND POWER; CONTROLLER; DFIG; RIDE;
D O I
10.1007/978-981-10-4762-6_33
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical energy is required to run everyday appliances. It is generated by from conventional energy sources, which are exhaustible; therefore, the importance of non-conventional energy sources is increasing by the hour. Wind energy as an energy source is non-polluting and does not pose any threat to nature. For utilizing this source of energy, it is imperative to find suitable ways to harness it. This paper involves simulation of a DFIG for wind energy applications its investigation under different network fault conditions, both symmetrical and asymmetrical. The simulation is carried out with the aid of Simulink toolbox in MATLAB.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 50 条
  • [31] Improved Demagnetization Control of a Doubly-Fed Induction Generator Under Balanced Grid Fault
    Zhou, Linyuan
    Liu, Jinjun
    Zhou, Sizhan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (12) : 6695 - 6705
  • [32] Dynamic response of doubly fed induction generator variable speed wind turbine under fault
    El-Sattar, A. A.
    Saad, N. H.
    El-Dein, M. Z. Shams
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (07) : 1240 - 1246
  • [33] Effective protection for doubly fed induction generator-based wind turbines under three-phase fault conditions
    J. J. Justo
    F. Mwasilu
    J. W. Jung
    Electrical Engineering, 2018, 100 : 543 - 556
  • [34] Effective protection for doubly fed induction generator-based wind turbines under three-phase fault conditions
    Justo, J. J.
    Mwasilu, F.
    Jung, J. W.
    ELECTRICAL ENGINEERING, 2018, 100 (02) : 543 - 556
  • [35] Current sensor fault detection and reconfiguration for a Doubly Fed Induction Generator
    Rothenhagen, Kai
    Fuchs, Friedrich W.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 2732 - 2738
  • [36] The Research on the Characteristic of Fault Current of Doubly-Fed Induction Generator
    Ao-Yang, Han
    Zhe, Zhang
    Xiang-Gen, Yin
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 947 - 950
  • [37] Voltage sensor fault detection and reconfiguration for a doubly fed induction generator
    Rothenhagen, Kai
    Thomsen, Soenke
    Fuchs, Friedrich W.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS & DRIVES, 2007, : 256 - 261
  • [38] Open switch fault diagnosis for a doubly-fed induction generator
    Sae-Kok, W.
    Grant, D. M.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 368 - +
  • [39] Additive and multiplicative fault diagnosis for a doubly-fed induction generator
    Boulkroune, Boulaid
    Galvez-Carrillo, Manuel
    Kinnaert, Michel
    2011 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), 2011, : 1302 - 1308
  • [40] Protection Scheme Switch-Timing for Doubly-Fed Induction Generator during Fault Conditions
    Yang, Jin
    O'Reilly, John
    Fletcher, John E.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1295 - +