Investigation of Doubly Fed Induction Generator Behavior Under Symmetrical and Asymmetrical Fault Conditions

被引:0
|
作者
Tamvada, Karthik [1 ]
Umashankar, S. [1 ]
Sanjeevikumar, P. [2 ]
机构
[1] VIT Univ, Sch Elect Engn, Vellore, Tamil Nadu, India
[2] Univ Johannesburg, Dept Elect & Elect Engn, Johannesburg, South Africa
关键词
DFIG; Fault analysis; Modeling; Simulation; Electric grid; ENERGY-CONVERSION SYSTEM; GRID INTEGRATION; WIND POWER; CONTROLLER; DFIG; RIDE;
D O I
10.1007/978-981-10-4762-6_33
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical energy is required to run everyday appliances. It is generated by from conventional energy sources, which are exhaustible; therefore, the importance of non-conventional energy sources is increasing by the hour. Wind energy as an energy source is non-polluting and does not pose any threat to nature. For utilizing this source of energy, it is imperative to find suitable ways to harness it. This paper involves simulation of a DFIG for wind energy applications its investigation under different network fault conditions, both symmetrical and asymmetrical. The simulation is carried out with the aid of Simulink toolbox in MATLAB.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 50 条
  • [41] Control of a doubly-fed induction generator under unbalanced conditions considering the converter limits
    Gomis-Bellmunt, Oriol
    Junyent-Ferre, Adria
    Sumper, Andreas
    Sudria-Andreu, Antoni
    Mata, Montserrat
    Sala, Marc
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 1718 - +
  • [42] Control Strategy of Doubly-Fed Induction Generator under Zero Voltage Fault of Power Grid
    Ye, Yi
    Yang, Zelin
    Hu, Jiawei
    Yi, Haopeng
    Zhang, Lu
    SUSTAINABILITY, 2022, 14 (23)
  • [43] Levenberg-Marquardt SMC control of Grid-Tied Doubly Fed Induction Generator (DFIG) using FRT Schemes under Symmetrical Fault
    Azeem, Babar
    Udal, Z.
    Rehman, F.
    Ali, S. M.
    Haider, A.
    Saeed, S.
    Hussain, I.
    Mehmood, C. A.
    Khan, B.
    2018 1ST IEEE INTERNATIONAL CONFERENCE ON POWER, ENERGY AND SMART GRID (ICPESG), 2018,
  • [44] Doubly-fed induction generator ride-through fault capability using resonant controllers for asymmetrical voltage sags
    Mendes, Victor Flores
    de Sousa, Clodualdo Venicio
    Hofmann, Wilfried
    Silva, Selenio Rocha
    IET RENEWABLE POWER GENERATION, 2015, 9 (07) : 783 - 791
  • [45] A fault prediction framework for Doubly-fed induction generator under time-varying operating conditions driven by digital twin
    Ma, Junyan
    Yuan, Yiping
    Chen, Pan
    IET ELECTRIC POWER APPLICATIONS, 2023, 17 (04) : 499 - 521
  • [46] Parameterization of a synchronous generator to represent a doubly fed induction generator with chopper protection for fault studies
    Martinez, Jorge
    Kjaer, Philip C.
    Rodriguez, Pedro
    Teodorescu, Remus
    WIND ENERGY, 2011, 14 (01) : 107 - 118
  • [47] Doubly Fed Induction Wind Generator Model and Its Operation Investigation
    Shu, J.
    Zhang, B. H.
    Cheng, L. Y.
    Wang, C. G.
    Li, P.
    Bo, Z. Q.
    Klimek, A.
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2482 - +
  • [48] Investigation of Control for Grid Integrated Doubly Fed Induction Wind Generator
    Shu, J.
    Zhang, B. H.
    Wang, C. G.
    Bo, Z. Q.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 2893 - +
  • [49] Bearing Fault Detection for Doubly fed Induction Generator Based on Stator Current
    Tang, Hong
    Dai, Hong-Liang
    Du, Yi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (05) : 5267 - 5276
  • [50] Actuator Fault Diagnosis Approach for Doubly Fed Induction Generator of Wind Turbine
    Idrissi, I.
    Chafouk, H.
    El Bachtiri, R.
    2019 4TH CONFERENCE ON CONTROL AND FAULT TOLERANT SYSTEMS (SYSTOL), 2019, : 378 - 383