Magnetic resonance imaging (MRI);
3D FLAIR;
Iterative denoising;
Brain MRI;
MULTIPLE-SCLEROSIS;
2D FLAIR;
SUPPRESSION;
D O I:
10.1016/j.diii.2021.09.004
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: The purpose of this study was to prospectively evaluate image quality of three-dimensional fluid attenuated inversion recovery (3D-FLAIR) sequence acquired with a high acceleration factor and reconstructed with iterative denoising (ID) for brain magnetic resonance imaging (MRI) at 3-T. Material and methods: Patients with brain tumor who underwent brain MRI were consecutively included. Two 3D-FLAIR sequences were successively performed for each patient. A first conventional FLAIR acquisition (conv-FLAIR) was performed with an acceleration factor of 6. The second acquisition was performed with an increased acceleration factor of 9. Two series one without ID (acc-FLAIR) and one with ID (acc-FLAIR-ID) were reconstructed. Two neuroradiologists independently assessed image quality, deep brain nuclei visualization and white matter/gray matter (WM/GM) differentiation on a 4-point scale. Results: Thirty patients with brain tumor were consecutively included in this study. There were 16 women and 14 men with a mean age of 54 +/- 17 (SD) years (range: 22-78 years). Scanning time of Acc-FLAIR-ID and Acc-FLAIR (4 min 40 sec) was 37% shorter than that of conv-FLAIR (2 min 50 sec) (P < 0.01). Improved image quality score was significantly different for both conv-FLAIR and acc-FLAIR-ID compared to acc-FLAIR (P < 0.01 for both). WM/GM differentiation score of conv-FLAIR was not significantly different compared to accFLAIR-ID (P = 0.10). Improved WM/GM differentiation score was different for both sequences compared to acc-FLAIR (P = 0.017 and P < 0.001). Deep brain nuclei visualization score was not different between convFLAIR and acc-FLAIR-ID (P = 0.71). However, the improved deep brain nuclei visualization score was signifi-cantly different for both sequences compared to acc-FLAIR (P < 0.001 for both). Conclusion: Scanning time of 3D-FLAIR sequence using a high acceleration factor reconstructed with ID algorithm can be reduced by 37% while preserving image quality for brain MRI. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
机构:
Mayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
Indiana Univ Sch Med, Radiol & Imaging Sci, Indianapolis, IN 46202 USA
Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USAMayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
James, Judy R.
Panda, Anshuman
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
Indiana Univ Sch Med, Radiol & Imaging Sci, Indianapolis, IN 46202 USA
Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USAMayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
Panda, Anshuman
Lin, Chen
论文数: 0引用数: 0
h-index: 0
机构:
Indiana Univ Sch Med, Radiol & Imaging Sci, Indianapolis, IN 46202 USAMayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
Lin, Chen
Dydak, Ulrike
论文数: 0引用数: 0
h-index: 0
机构:
Indiana Univ Sch Med, Radiol & Imaging Sci, Indianapolis, IN 46202 USA
Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USAMayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
Dydak, Ulrike
Dale, Brian M.
论文数: 0引用数: 0
h-index: 0
机构:
Siemens Med Solut, MR R&D, Cary, NC USAMayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
Dale, Brian M.
Bansal, Navin
论文数: 0引用数: 0
h-index: 0
机构:
Indiana Univ Sch Med, Radiol & Imaging Sci, Indianapolis, IN 46202 USAMayo Clin, Dept Radiol, Scottsdale, AZ 85259 USA
机构:
Govt Med Coll, Dept Radiol, Omandurar Govt Estate, Madras, Tamil Nadu, IndiaGovt Med Coll, Dept Radiol, Omandurar Govt Estate, Madras, Tamil Nadu, India
Kandasamy, Geetha
Peter, S. Babu
论文数: 0引用数: 0
h-index: 0
机构:
Madras Med Coll & Govt Gen Hosp, Dept Radiol, Madras, Tamil Nadu, IndiaGovt Med Coll, Dept Radiol, Omandurar Govt Estate, Madras, Tamil Nadu, India
Peter, S. Babu
Priya, R. Bharathi
论文数: 0引用数: 0
h-index: 0
机构:
Govt Med Coll, Dept Radiol, Omandurar Govt Estate, Madras, Tamil Nadu, IndiaGovt Med Coll, Dept Radiol, Omandurar Govt Estate, Madras, Tamil Nadu, India
机构:
Fdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, FranceFdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, France
Lecler, A.
El Sanharawi, I.
论文数: 0引用数: 0
h-index: 0
机构:
Fdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, FranceFdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, France
El Sanharawi, I.
El Methni, J.
论文数: 0引用数: 0
h-index: 0
机构:
Paris Descartes Univ, Sorbonne Paris Cite, CNRS, UMR 8145,MAP5 Lab,Dept Biostat, Paris, FranceFdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, France
El Methni, J.
Gout, O.
论文数: 0引用数: 0
h-index: 0
机构:
Fdn Ophtalmol Adolphe Rothschild, Dept Neurol, Paris, FranceFdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, France
Gout, O.
Koskas, P.
论文数: 0引用数: 0
h-index: 0
机构:
Fdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, FranceFdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, France
Koskas, P.
Savatovsky, J.
论文数: 0引用数: 0
h-index: 0
机构:
Fdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, FranceFdn Ophtalmol Adolphe Rothschild, Dept Neuroradiol, 25 Rue Manin, F-75019 Paris, France