Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T

被引:11
|
作者
Eliezer, Michael [1 ,2 ]
Vaussy, Alexis [3 ]
Toupin, Solenn [3 ]
Barbe, Remy [1 ]
Kannengiesser, Stephan [4 ]
Stemmer, Alto [4 ]
Houdart, Emmanuel [1 ,2 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
[2] Univ Paris, Fac Med, F-75010 Paris, France
[3] Siemens Healthineers France, F-93210 St Denis, France
[4] Siemens Healthineers, D-91052 Erlangen, Germany
关键词
Magnetic resonance imaging (MRI); 3D FLAIR; Iterative denoising; Brain MRI; MULTIPLE-SCLEROSIS; 2D FLAIR; SUPPRESSION;
D O I
10.1016/j.diii.2021.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to prospectively evaluate image quality of three-dimensional fluid attenuated inversion recovery (3D-FLAIR) sequence acquired with a high acceleration factor and reconstructed with iterative denoising (ID) for brain magnetic resonance imaging (MRI) at 3-T. Material and methods: Patients with brain tumor who underwent brain MRI were consecutively included. Two 3D-FLAIR sequences were successively performed for each patient. A first conventional FLAIR acquisition (conv-FLAIR) was performed with an acceleration factor of 6. The second acquisition was performed with an increased acceleration factor of 9. Two series one without ID (acc-FLAIR) and one with ID (acc-FLAIR-ID) were reconstructed. Two neuroradiologists independently assessed image quality, deep brain nuclei visualization and white matter/gray matter (WM/GM) differentiation on a 4-point scale. Results: Thirty patients with brain tumor were consecutively included in this study. There were 16 women and 14 men with a mean age of 54 +/- 17 (SD) years (range: 22-78 years). Scanning time of Acc-FLAIR-ID and Acc-FLAIR (4 min 40 sec) was 37% shorter than that of conv-FLAIR (2 min 50 sec) (P < 0.01). Improved image quality score was significantly different for both conv-FLAIR and acc-FLAIR-ID compared to acc-FLAIR (P < 0.01 for both). WM/GM differentiation score of conv-FLAIR was not significantly different compared to accFLAIR-ID (P = 0.10). Improved WM/GM differentiation score was different for both sequences compared to acc-FLAIR (P = 0.017 and P < 0.001). Deep brain nuclei visualization score was not different between convFLAIR and acc-FLAIR-ID (P = 0.71). However, the improved deep brain nuclei visualization score was signifi-cantly different for both sequences compared to acc-FLAIR (P < 0.001 for both). Conclusion: Scanning time of 3D-FLAIR sequence using a high acceleration factor reconstructed with ID algorithm can be reduced by 37% while preserving image quality for brain MRI. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [21] Comparison between 3D SPACE FLAIR and 3D TSE FLAIR in Meniere's disease
    Bernaerts, Anja
    Janssen, Nick
    Wuyts, Floris L.
    Blaivie, Catherine
    Vanspauwen, Robby
    van Dinther, Joost
    Zarowski, Andrzej
    Offeciers, Erwin
    Deckers, Filip
    Casselman, Jan W.
    De Foer, Bert
    NEURORADIOLOGY, 2022, 64 (05) : 1011 - 1020
  • [22] Phased array 3D MR spectroscopic imaging of the brain at 7 T
    Xu, Duan
    Cunningham, Charles H.
    Chen, Albert P.
    Li, Yan
    Kelley, Douglas A. C.
    Mukherjee, Pratik
    Pauly, John M.
    Nelson, Sarah J.
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (09) : 1201 - 1206
  • [23] MR image denoising method for brain surface 3D modeling
    Zhao D.-X.
    Liu P.-J.
    Zhang D.-G.
    Optoelectronics Letters, 2014, 10 (6) : 477 - 480
  • [24] MR image denoising method for brain surface 3D modeling
    赵德新
    刘朋杰
    张德干
    Optoelectronics Letters, 2014, 10 (06) : 477 - 480
  • [25] 3T MR Imaging of the Shoulder: Is MR Arthrography Necessary?
    Magee, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [26] High-Resolution 3T MR Neurography of the Brachial Plexus and Its Branches, with Emphasis on 3D Imaging
    Chhabra, A.
    Thawait, G. K.
    Soldatos, T.
    Thakkar, R. S.
    Del Grande, F.
    Chalian, M.
    Carrino, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : 486 - 497
  • [27] Optimal single 3T MR imaging sequence for HDR brachytherapy of cervical cancer
    Dempsey, Claire
    Arm, Jameen
    Best, Leah
    Govindarajulu, Geetha
    Capp, Anne
    O'Brien, Peter
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 3 - 9
  • [28] A rapid 3D cine MR sequence for cardiac imaging
    Alley, MT
    Shifrin, RY
    Pelc, NJ
    Herfkens, RJ
    RADIOLOGY, 1997, 205 : 303 - 303
  • [29] Comparison between 3D SPACE FLAIR and 3D TSE FLAIR in Menière’s disease
    Anja Bernaerts
    Nick Janssen
    Floris L. Wuyts
    Cathérine Blaivie
    Robby Vanspauwen
    Joost van Dinther
    Andrzej Zarowski
    Erwin Offeciers
    Filip Deckers
    Jan W. Casselman
    Bert De Foer
    Neuroradiology, 2022, 64 : 1011 - 1020
  • [30] Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients
    Frydrychowicz, Alex
    Bley, Thorsten A.
    Winterer, Jan T.
    Harloff, Andreas
    Langer, Mathias
    Hennig, Juergen
    Markl, Michael
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (04) : 187 - 195