Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T

被引:11
|
作者
Eliezer, Michael [1 ,2 ]
Vaussy, Alexis [3 ]
Toupin, Solenn [3 ]
Barbe, Remy [1 ]
Kannengiesser, Stephan [4 ]
Stemmer, Alto [4 ]
Houdart, Emmanuel [1 ,2 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
[2] Univ Paris, Fac Med, F-75010 Paris, France
[3] Siemens Healthineers France, F-93210 St Denis, France
[4] Siemens Healthineers, D-91052 Erlangen, Germany
关键词
Magnetic resonance imaging (MRI); 3D FLAIR; Iterative denoising; Brain MRI; MULTIPLE-SCLEROSIS; 2D FLAIR; SUPPRESSION;
D O I
10.1016/j.diii.2021.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to prospectively evaluate image quality of three-dimensional fluid attenuated inversion recovery (3D-FLAIR) sequence acquired with a high acceleration factor and reconstructed with iterative denoising (ID) for brain magnetic resonance imaging (MRI) at 3-T. Material and methods: Patients with brain tumor who underwent brain MRI were consecutively included. Two 3D-FLAIR sequences were successively performed for each patient. A first conventional FLAIR acquisition (conv-FLAIR) was performed with an acceleration factor of 6. The second acquisition was performed with an increased acceleration factor of 9. Two series one without ID (acc-FLAIR) and one with ID (acc-FLAIR-ID) were reconstructed. Two neuroradiologists independently assessed image quality, deep brain nuclei visualization and white matter/gray matter (WM/GM) differentiation on a 4-point scale. Results: Thirty patients with brain tumor were consecutively included in this study. There were 16 women and 14 men with a mean age of 54 +/- 17 (SD) years (range: 22-78 years). Scanning time of Acc-FLAIR-ID and Acc-FLAIR (4 min 40 sec) was 37% shorter than that of conv-FLAIR (2 min 50 sec) (P < 0.01). Improved image quality score was significantly different for both conv-FLAIR and acc-FLAIR-ID compared to acc-FLAIR (P < 0.01 for both). WM/GM differentiation score of conv-FLAIR was not significantly different compared to accFLAIR-ID (P = 0.10). Improved WM/GM differentiation score was different for both sequences compared to acc-FLAIR (P = 0.017 and P < 0.001). Deep brain nuclei visualization score was not different between convFLAIR and acc-FLAIR-ID (P = 0.71). However, the improved deep brain nuclei visualization score was signifi-cantly different for both sequences compared to acc-FLAIR (P < 0.001 for both). Conclusion: Scanning time of 3D-FLAIR sequence using a high acceleration factor reconstructed with ID algorithm can be reduced by 37% while preserving image quality for brain MRI. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [41] Generalized Multiple-Layer Appearance of the Cerebral Cortex with 3D FLAIR 7.0-T MR Imaging
    Zwanenburg, Jaco J. M.
    Hendrikse, Jeroen
    Luijten, Peter R.
    RADIOLOGY, 2012, 262 (03) : 995 - 1001
  • [42] Effectiveness of 3D T2-Weighted FLAIR FSE Sequences with Fat Suppression for Detection of Brain MR Imaging Signal Changes in Children
    Mascalchi, M.
    Bianchi, A.
    Basile, M.
    Gulino, P.
    Trifan, M. R.
    Difeo, D.
    Bartolini, E.
    Defilippi, C.
    Diciotti, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2376 - 2381
  • [43] Assessment of central vein sign conspicuity in multicenter 3t flair☆ imaging
    Martin, M.
    Cao, Q.
    Renner, B.
    Daboul, L.
    O'Donnell, C.
    Moreno-Dominguez, D.
    Rodrigues, P.
    Derbyshire, J.
    Azevedo, C.
    Bar-Or, A.
    Caverzasi, E.
    Calabresi, P.
    Cree, B.
    Freeman, L.
    Henry, R.
    Longbrake, E.
    Oh, J.
    Papinutto, N.
    Samudralwar, R.
    Schindler, M.
    Sotirchos, E.
    Sicotte, N.
    Solomon, A.
    Shinohara, R.
    Reich, D.
    Ontaneda, D.
    Sati, P.
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (3_SUPPL) : 376 - 377
  • [44] Reliability of Central Vein Sign Imaging With 3T FLAIR* in a Multicenter Study
    Martin, Melissa Lynne
    Cao, Quy
    Luskin, Elaina
    Renner, Brian
    Daboul, Lynn
    O'Donnell, Carly M.
    Rodrigues, Paulo
    Derbyshire, John
    Azevedo, Christina J.
    Bar-Or, Amit
    Caverzasi, Eduardo
    Calabresi, Peter
    Cree, Bruce A. C.
    Freeman, Leorah
    Henry, Roland G.
    Longbrake, Erin E.
    Oh, Jiwon
    Papinutto, Nico
    Pelletier, Daniel
    Prchkovska, Vesna
    Ramos, Marc
    Samudralwar, Rohini D.
    Schindler, Matthew K.
    Sotirchos, Elias S.
    Sicotte, Nancy L.
    Solomon, Andrew J.
    Reich, Daniel S.
    Ontaneda, Daniel
    Shinohara, Russell T.
    Sati, Pascal
    JOURNAL OF NEUROIMAGING, 2025, 35 (01)
  • [45] Trabecular bone imaging using a 3D adiabatic inversion recovery prepared ultrashort TE Cones sequence at 3T
    Ma, Ya-Jun
    Chen, Yanjun
    Li, Liang
    Cai, Zhenyu
    Wei, Zhao
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1640 - 1651
  • [46] Accelerated 3D self-gated cardiac cine imaging at 3T using a tiny golden angle and compressed sensing
    Xiaoyong Zhang
    Guoxi Xie
    Hanwei Chen
    Yanchun Zhu
    Zijun Wei
    Shi Su
    Fei Yan
    Bensheng Qiu
    Xin Liu
    Zhaoyang Fan
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [47] 3D imaging of the whole spine at 3T compared to 1.5T: Initial experiences
    Rodegerdts, EA
    Boss, A
    Riemarzik, K
    Lichy, M
    Schick, F
    Claussen, CD
    Schlemmer, HP
    ACTA RADIOLOGICA, 2006, 47 (05) : 488 - 493
  • [48] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [49] MR imaging of the internal auditory canal and inner ear at 3T: Comparison between 3D driven equilibrium and 3D balanced fast field echo sequences
    Byun, Jun Soo
    Kim, Hyung-Jin
    Yim, You Jeong
    Kim, Sung Tae
    Jeon, Pyoung
    Kim, Keon Ha
    Kim, Sam Soo
    Jeon, Yong Hwan
    Lee, Jiwon
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 212 - 218
  • [50] High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence
    Chen, Albert P.
    Cunningham, Charles H.
    Kurhanewicz, John
    Xu, Duan
    Hurd, Ralph E.
    Pauly, John M.
    Carvajal, Lucas
    Karpodinis, Kostas
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (07) : 825 - 832