On the possibility of real-time monitoring of glucose in cell culture by microdialysis using a fluorescent glucose binding protein sensor

被引:13
|
作者
Ge, Xudong [1 ]
Rao, Govind [1 ]
Tolosa, Leah [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
关键词
D O I
10.1021/bp070411k
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micrornolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 mu L/min or faster can be used, resulting in delay times of 1 min or less.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [41] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [42] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [43] A Large-scale System for Real-time Glucose Monitoring
    Vu, Long
    Pavuluri, Venkata N.
    Chang, Yuan-chi
    Turaga, Deepak S.
    Zhong, Alex
    Agrawal, Pratik
    Singh, Amit
    Jiang, Boyi
    Chirutha, Krishna
    2018 48TH ANNUAL IEEE/IFIP INTERNATIONAL CONFERENCE ON DEPENDABLE SYSTEMS AND NETWORKS WORKSHOPS (DSN-W), 2018, : 34 - 37
  • [44] Design and implementation of real-time continuous glucose monitoring instrument
    实时动态血糖监测器的设计与实现
    Liu, Hongying (liu_hongying@163.com), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [45] Is reimbursement for alerts and real-time continuous glucose monitoring needed?
    Norgaard, Kirsten
    Schmidt, Signe
    LANCET, 2021, 397 (10291): : 2230 - 2232
  • [46] Real-time monitoring and control of glucose and lactate concentrations in a mammalian cell perfusion reactor
    Ozturk, SS
    Thrift, JC
    Blackie, JD
    Naveh, D
    BIOTECHNOLOGY AND BIOENGINEERING, 1997, 53 (04) : 372 - 378
  • [47] Cell-based microfluidic biochip for electrochemical real-time monitoring of glucose and oxygen
    Rodrigues, N. Pereira
    Kimura, H.
    Sakai, Y.
    Fujii, T.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [48] Cell-based microfluidic biochip for the electrochemical real-time monitoring of glucose and oxygen
    Rodrigues, N. Pereira
    Sakai, Y.
    Fujii, T.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (02) : 608 - 613
  • [49] A Feasibility Study to Detect Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring
    Nally, Laura M.
    Bondy, Nicholas W.
    Doiev, Jasmine
    Buckingham, Bruce
    Wilson, Darrell
    DIABETES, 2018, 67
  • [50] Real-time myocardial glucose measurement using biosensors
    Eiferman, Daniel S.
    Nguyen, Long
    Perez-Tamayo, R. Anthony
    ASAIO JOURNAL, 2008, 54 (01) : 120 - 123