On the possibility of real-time monitoring of glucose in cell culture by microdialysis using a fluorescent glucose binding protein sensor

被引:13
|
作者
Ge, Xudong [1 ]
Rao, Govind [1 ]
Tolosa, Leah [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
关键词
D O I
10.1021/bp070411k
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micrornolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 mu L/min or faster can be used, resulting in delay times of 1 min or less.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [31] Use of a real-time glucose sensor (VIA model 121) for glucose clamp studies
    Baloga, J
    Edelman, SV
    DIABETES, 1996, 45 : 519 - 519
  • [32] Real-time amino acid and glucose monitoring system for the automatic control of nutrient feeding in CHO cell culture using Raman spectroscopy
    Domjan, Julia
    Pantea, Eszter
    Gyurkes, Martin
    Madarasz, Lajos
    Kozak, Dora
    Farkas, Attila
    Horvath, Balazs
    Nagy, Zsombor Kristof
    Marosi, Gyorgy
    Hirsch, Edit
    BIOTECHNOLOGY JOURNAL, 2022, 17 (05)
  • [33] Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes
    Garg, SK
    Schwartz, S
    Edelman, SV
    DIABETES CARE, 2004, 27 (03) : 734 - 738
  • [34] Impact of real-time continuous glucose monitoring on glucose variability in critically ill patients
    R Brunner
    R Kitzberger
    W Miehsler
    V Fuhrmann
    C Madl
    U Holzinger
    Critical Care, 14 (Suppl 1):
  • [35] Continuous Glucose Monitoring Using a Novel Glucose/Galactose Binding Protein: Results of a 12-Hour Feasibility Study with the Becton Dickinson Glucose/Galactose Binding Protein Sensor
    Judge, Kevin
    Morrow, Linda
    Lastovich, Alexander G.
    Kurisko, David
    Keith, Steven C.
    Hartsell, Jacob
    Roberts, Bruce
    McVey, Elaine
    Weidemaier, Kristin
    Win, Khin
    Hompesch, Marcus
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (03) : 309 - 317
  • [36] The accuracy and efficacy of Real-Time Continuous Glucose Monitoring sensor in patients with type 1 diabetes
    Mastrototaro, John
    Shin, John
    Marcus, Alan
    Sulur, Giri
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (05) : 385 - 390
  • [37] Human sweat-based wearable glucose sensor on cotton fabric for real-time monitoring
    Anoop Singh
    Asha Sharma
    Sandeep Arya
    Journal of Analytical Science and Technology, 13
  • [38] Human sweat-based wearable glucose sensor on cotton fabric for real-time monitoring
    Singh, Anoop
    Sharma, Asha
    Arya, Sandeep
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2022, 13 (01)
  • [39] New perspectives on real-time continuous glucose monitoring Comment
    Stechova, Katerina
    LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (04): : 235 - 236
  • [40] Accuracy of a new real-time continuous glucose monitoring algorithm
    Navas de Solis, M. S.