On the possibility of real-time monitoring of glucose in cell culture by microdialysis using a fluorescent glucose binding protein sensor

被引:13
|
作者
Ge, Xudong [1 ]
Rao, Govind [1 ]
Tolosa, Leah [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
关键词
D O I
10.1021/bp070411k
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micrornolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 mu L/min or faster can be used, resulting in delay times of 1 min or less.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [21] Reliability of real-time continuous glucose monitoring in infants
    Tomotaki, Seiichi
    Toyoshima, Katsuaki
    Shimokaze, Tomoyuki
    Kawai, Masahiko
    PEDIATRICS INTERNATIONAL, 2019, 61 (10) : 1001 - 1006
  • [22] Noninvasive Real-Time Glucose Monitoring Is in the Near Future
    Hirsch, Irl B.
    Tirosh, Amir
    Navon, Ami
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (09) : 661 - 666
  • [23] Clinical Use of Real-Time Continuous Glucose Monitoring
    Battelino, Tadej
    Bolinder, Jan
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 218 - 222
  • [24] Benefits of Real-Time Continuous Glucose Monitoring in Pregnancy
    Yamamoto, Jennifer M.
    Murphy, Helen R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S8 - S14
  • [25] The use of MiniMed CGMS in real-time glucose monitoring
    Chee, F
    Fernando, T
    Savkin, A
    van Heerden, P
    ANZIIS 2001: PROCEEDINGS OF THE SEVENTH AUSTRALIAN AND NEW ZEALAND INTELLIGENT INFORMATION SYSTEMS CONFERENCE, 2001, : 159 - 164
  • [26] The Medtronic minimed Continuous Glucose Monitoring System for patient use: real-time sensor glucose values and trend information
    Kaufman, F
    Halvorson, M
    Carpenter, S
    Cooper, K
    Kolopp, M
    Mueller, J
    DIABETOLOGIA, 2004, 47 : A316 - A316
  • [27] Interstitial fluid glucose time-lag correction for real-time continuous glucose monitoring
    Keenan, D. Barry
    Mastrototaro, John J.
    Weinzimer, Stuart A.
    Steil, Garry M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (01) : 81 - 89
  • [28] Real-Time and Online Monitoring of Glucose Contents by Using Molecular Imprinted Polymer-Based IDEs Sensor
    Asghar, Nazia
    Mustafa, Ghulam
    Yasinzai, Maimoona
    Al-Soud, Yaseen A.
    Lieberzeit, Peter A.
    Latif, Usman
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2019, 189 (04) : 1156 - 1166
  • [29] Real-Time and Online Monitoring of Glucose Contents by Using Molecular Imprinted Polymer-Based IDEs Sensor
    Nazia Asghar
    Ghulam Mustafa
    Maimoona Yasinzai
    Yaseen A. Al-Soud
    Peter A. Lieberzeit
    Usman Latif
    Applied Biochemistry and Biotechnology, 2019, 189 : 1156 - 1166
  • [30] Continuous Glucose Monitoring by Real Time Sensor in Interstitial Fluid
    Honsova, Sarka
    Navratil, Tomas
    XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 63 - 67