On the possibility of real-time monitoring of glucose in cell culture by microdialysis using a fluorescent glucose binding protein sensor

被引:13
|
作者
Ge, Xudong [1 ]
Rao, Govind [1 ]
Tolosa, Leah [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
关键词
D O I
10.1021/bp070411k
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micrornolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 mu L/min or faster can be used, resulting in delay times of 1 min or less.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [11] A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture
    Pemberton, R. M.
    Xu, J.
    Pittson, R.
    Drago, G. A.
    Griffiths, J.
    Jackson, S. K.
    Hart, J. P.
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2448 - 2453
  • [12] Amperometric glucose sensor for real time extracellular glucose monitoring in microfluidic device
    Ges, Igor A.
    Baudenbacher, Franz J.
    NSTI NANOTECH 2008, VOL 3, TECHNICAL PROCEEDINGS: MICROSYSTEMS, PHOTONICS, SENSORS, FLUIDICS, MODELING, AND SIMULATION, 2008, : 253 - +
  • [13] Assessment of glucose kinetics with real-time continuous glucose monitoring during labor
    Maki, Jota
    Eto, Eriko
    Tamada, Shoko
    Mitsui, Takashi
    Hayata, Kei
    Nakamura, Keiichiro
    Hiramatsu, Yuji
    Masuyama, Hisashi
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2019, 45 (09) : 1851 - 1859
  • [14] Real-time glucose monitoring system containing enzymatic sensor and enzymatic reference electrodes
    Ramašauskas, Lukas
    Meškys, Rolandas
    Ratautas, Dalius
    Biosensors and Bioelectronics, 2021, 164
  • [15] Real-time glucose monitoring system containing enzymatic sensor and enzymatic reference electrodes
    Ramasauskas, Lukas
    Meskys, Rolandas
    Ratautas, Dalius
    BIOSENSORS & BIOELECTRONICS, 2020, 164
  • [16] Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish
    Endo, Hideaki
    Yonemori, Yuki
    Hibi, Kyoko
    Ren, Huifeng
    Hayashi, Tetsuhito
    Tsugawa, Wakako
    Sode, Koji
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1417 - 1423
  • [17] Practical Aspects of Real-Time Continuous Glucose Monitoring
    Gilliam, Lisa K.
    Hirsch, Irl B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S75 - S82
  • [18] Real-Time Continuous Glucose Monitoring in Preterm Infants
    Joseph, Rachel
    Rosa, Jenna Hope-Altomari
    NEONATAL NETWORK, 2022, 41 (06): : 376 - 376
  • [19] Real-Time Improvement of Continuous Glucose Monitoring Accuracy
    Facchinetti, Andrea
    Sparacino, Giovanni
    Guerra, Stefania
    Luijf, Yoeri M.
    DeVries, J. Hans
    Mader, Julia K.
    Ellmerer, Martin
    Benesch, Carsten
    Heinemann, Lutz
    Bruttomesso, Daniela
    Avogaro, Angelo
    Cobelli, Claudio
    DIABETES CARE, 2013, 36 (04) : 793 - 800
  • [20] Advances in electrochemical sensors for real-time glucose monitoring
    Harun-Or-Rashid, Md.
    Aktar, Most. Nazmin
    Preda, Veronica
    Nasiri, Noushin
    SENSORS & DIAGNOSTICS, 2024, 3 (06): : 893 - 913