On the possibility of real-time monitoring of glucose in cell culture by microdialysis using a fluorescent glucose binding protein sensor

被引:13
|
作者
Ge, Xudong [1 ]
Rao, Govind [1 ]
Tolosa, Leah [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
关键词
D O I
10.1021/bp070411k
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micrornolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 mu L/min or faster can be used, resulting in delay times of 1 min or less.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [1] BIOT 271-Monitoring of glucose in cell culture by glucose binding protein (GBP) combined with ultraslow microdialysis
    Ge, Xudong
    Hanson, Michael A.
    Rao, Govind
    Tolosa, Leah
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [2] A dual sensor for real-time monitoring of glucose and oxygen
    Zhang, Liqiang
    Su, Fengyu
    Buizer, Sean
    Lu, Hongguang
    Gao, Weimin
    Tian, Yanqing
    Meldrum, Deirdre
    BIOMATERIALS, 2013, 34 (38) : 9779 - 9788
  • [3] BIOT 423-Binding proteins as potential sensors for real- time monitoring of glucose and glutamine in mammalian cell culture using microdialysis.
    Sriram, Archana
    Mupparapu, KarunaSri
    Ge, Xudong
    Rao, Govind
    Tolosa, Leah
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 236
  • [4] REAL-TIME LAG COMPENSATION FOR A SUBCUTANEOUSLY IMPLANTED FLUORESCENT GLUCOSE SENSOR
    Wang, X.
    Rajaraman, S.
    DeHennis, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A76 - A76
  • [5] THE ACCURACY OF CONTINUOUS REAL-TIME GLUCOSE MEASUREMENT BY MICRODIALYSIS
    Blixt, C.
    Rooyackers, O.
    Wernerman, J.
    INTENSIVE CARE MEDICINE, 2011, 37 : S99 - S99
  • [6] The Role of Real-Time Glucose Monitoring
    Bernot, John
    Patel, Manali
    Kirk, Julienne K.
    JOURNAL OF DIABETES & METABOLISM, 2016, 7 (04)
  • [7] Development of Fluorescent Glucose Bioprobes and Their Application on Real-Time and Quantitative Monitoring of Glucose Uptake in Living Cells
    Lee, Hyang Yeon
    Lee, Jae Jeong
    Park, Jongmin
    Park, Seung Bum
    CHEMISTRY-A EUROPEAN JOURNAL, 2011, 17 (01) : 143 - 150
  • [8] Accuracy of real-time glucose values using continuous glucose monitoring:: the Guardian™ II continuous glucose monitoring system
    Schwartz, SL
    Buchea, O
    Shin, J
    Hoss, U
    Shah, R
    DIABETOLOGIA, 2004, 47 : A315 - A315
  • [9] Real-time continuous glucose monitoring in the ICU
    J Gios
    B Manuel-y-Keenoy
    P Rogiers
    Critical Care, 19 (Suppl 1):
  • [10] Real-time imaging of glucose uptake in the substantia nigra pars reticulata using a fluorescent glucose tracer
    Yamada, Katsuya
    Takeo, Teruko
    Takatsuna, Masafumi
    Suga, Sechiko
    NEUROSCIENCE RESEARCH, 2007, 58 : S182 - S182