3D prompt gamma imaging for proton beam range verification

被引:105
|
作者
Draeger, E. [1 ]
Mackin, D. [2 ]
Peterson, S. [3 ]
Chen, H. [1 ]
Avery, S. [4 ]
Beddar, S. [2 ,5 ]
Polf, J. C. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, 22 South Greene St, Baltimore, MD 21201 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[3] Univ Cape Town, Dept Phys, ZA-7700 Cape Town, South Africa
[4] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd, Philadelphia, PA 19104 USA
[5] Univ Texas Houston, Grad Sch Biomed Sci Houston, 6767 Bertner Ave, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 03期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Compton imaging; prompt gamma; proton therapy; range verification; COMPTON CAMERA; RAY EMISSION; THERAPY; RECONSTRUCTION; RADIOTHERAPY; ENERGY; IRRADIATION; SIMULATION; DETECTORS; RADIATION;
D O I
10.1088/1361-6560/aaa203
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC placed at three different locations along the proton beam path. We evaluated the ability of the CC to produce images at each location for two clinical scenarios: (1) the delivery of a single 2 Gy pencil beam from a hypo-fractionated treatment (similar to 9 x 10(8) protons), and (2) a single pencil beam from a standard treatment (similar to 1 x 10(8) protons). Additionally, the data measured at each location were combined to simulate measurements with a larger scale, clinical CC and its ability to image shifts in the Bragg peak (BP) range for both clinical scenarios. With our prototype CC, the location of the distal end of the BP could be seen with the CC placed up to 4 cm proximal or distal to the BP distal falloff. Using the data from the simulated full scale clinical CC, 3D images of the PG emission were produced with the delivery of as few as 1 x 10(8) protons, and shifts in the proton beam range as small as 2 mm could be detected for delivery of a 2 Gy spot. From these results we conclude that 3D PG imaging for proton range verification under clinical beam delivery conditions is possible with a single CC.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Prompt-Gamma Spatial Energy-Distribution in a Proton Therapy Plan for Beam Range Verification
    Vella, A.
    Fiorini, F.
    Van den Heuvel, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E281 - E281
  • [22] Proton range verification through prompt gamma-ray spectroscopy
    Verburg, Joost M.
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7089 - 7106
  • [23] A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning
    Jiang, Zhuoran
    Polf, Jerimy C.
    Barajas, Carlos A.
    Gobbert, Matthias K.
    Ren, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (07):
  • [24] Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1063 - 1082
  • [25] Analytical computation of prompt gamma ray emission and detection for proton range verification
    Sterpin, E.
    Janssens, G.
    Smeets, J.
    Stappen, Francois Vander
    Prieels, D.
    Priegnitz, Marlen
    Perali, Irene
    Vynckier, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4915 - 4946
  • [26] Prompt Gamma Imaging for range verification in Carbon Ion Radiation Therapy
    Idrissi, Aicha Bourkadi
    Borghi, Giacomo
    Donetti, Marco
    Pullia, Marco
    Casamichiela, Francesco
    Mazzucconi, Davide
    Agosteo, Stefano
    Fiorini, Ca
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3295 - S3299
  • [27] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17
  • [28] Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams
    Verburg, J.
    Bortfeld, T.
    Seco, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3548 - 3548
  • [29] Analytical Computation of Prompt Gamma Ray Emission and Detection for Proton Range Verification
    Sterpin, E.
    Janssens, G.
    Smeets, J.
    Prieels, D.
    Vynckier, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 550 - 550
  • [30] A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation
    Panaino, Costanza M. V.
    Mackay, Ranald I.
    Kirkby, Karen J.
    Taylor, Michael J.
    SCIENTIFIC REPORTS, 2019, 9 (1)