3D prompt gamma imaging for proton beam range verification

被引:105
|
作者
Draeger, E. [1 ]
Mackin, D. [2 ]
Peterson, S. [3 ]
Chen, H. [1 ]
Avery, S. [4 ]
Beddar, S. [2 ,5 ]
Polf, J. C. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, 22 South Greene St, Baltimore, MD 21201 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[3] Univ Cape Town, Dept Phys, ZA-7700 Cape Town, South Africa
[4] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd, Philadelphia, PA 19104 USA
[5] Univ Texas Houston, Grad Sch Biomed Sci Houston, 6767 Bertner Ave, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 03期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Compton imaging; prompt gamma; proton therapy; range verification; COMPTON CAMERA; RAY EMISSION; THERAPY; RECONSTRUCTION; RADIOTHERAPY; ENERGY; IRRADIATION; SIMULATION; DETECTORS; RADIATION;
D O I
10.1088/1361-6560/aaa203
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC placed at three different locations along the proton beam path. We evaluated the ability of the CC to produce images at each location for two clinical scenarios: (1) the delivery of a single 2 Gy pencil beam from a hypo-fractionated treatment (similar to 9 x 10(8) protons), and (2) a single pencil beam from a standard treatment (similar to 1 x 10(8) protons). Additionally, the data measured at each location were combined to simulate measurements with a larger scale, clinical CC and its ability to image shifts in the Bragg peak (BP) range for both clinical scenarios. With our prototype CC, the location of the distal end of the BP could be seen with the CC placed up to 4 cm proximal or distal to the BP distal falloff. Using the data from the simulated full scale clinical CC, 3D images of the PG emission were produced with the delivery of as few as 1 x 10(8) protons, and shifts in the proton beam range as small as 2 mm could be detected for delivery of a 2 Gy spot. From these results we conclude that 3D PG imaging for proton range verification under clinical beam delivery conditions is possible with a single CC.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Range verification of passively scattered proton beams based on prompt gamma time patterns
    Testa, Mauro
    Min, Chul Hee
    Verburg, Joost M.
    Schuemann, Jan
    Lu, Hsiao-Ming
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15): : 4181 - 4195
  • [42] A Fast Analytical Approach for Prompt Gamma and PET Predictions in a TPS for Proton Range Verification
    Kroniger, K.
    Herzog, M.
    Landry, G.
    Traneus, E.
    Dedes, G.
    Parodi, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3199 - 3199
  • [43] First clinical application of a prompt gamma based in vivo proton range verification system
    Richter, Christian
    Pausch, Guntram
    Barczyk, Steffen
    Priegnitz, Marlen
    Keitz, Isabell
    Thiele, Julia
    Smeets, Julien
    Stappen, Francois Vander
    Bombelli, Luca
    Fiorini, Carlo
    Hotoiu, Lucian
    Perali, Irene
    Prieels, Damien
    Enghardt, Wolfgang
    Baumann, Michael
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (02) : 232 - 237
  • [44] Clinical Translation of Prompt Gamma-Ray Spectroscopy for In Vivo Proton Range Verification
    Verburg, J.
    Ruggieri, T.
    Botas, P.
    Cascio, E.
    Hueso-Gonzalez, F.
    Rabe, M.
    BortfeId, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [45] Can Prompt Gamma Emission During Proton Therapy Provide in Situ Range Verification?
    Styczynski, J.
    Riley, K.
    Binns, P.
    Bortfeld, T.
    Paganetti, H.
    MEDICAL PHYSICS, 2009, 36 (06) : 2425 - +
  • [46] Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study
    Zarifi, Melek
    Guatelli, Susanna
    Bolst, David
    Hutton, Brian
    Rosenfeld, Anatoly
    Qi, Yujin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 197 - 206
  • [47] Prompt gamma imaging for the identification of proton range deviations due to anatomical change
    Xie, Y.
    Petzoldt, J.
    Janssens, G.
    Yin, L.
    Bentefour, E. H.
    Smeets, J.
    Prieels, D.
    Lustig, R. L.
    Lin, A.
    Teo, B. K.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S967 - S968
  • [48] Development of a New Prompt Gamma Ray Detection System to Achieve Range Verification in Full 3 Dimensions for Pencil-Beam Scanning Proton Therapy
    Panaino, C.
    Mackay, R.
    Kirkby, K.
    Taylor, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E419 - E420
  • [49] 3D imaging of microscopic structures using a proton beam
    Michelet-Habchi, C
    Incerti, S
    Aguer, P
    Barberet, P
    Gontier, E
    Guinefolleau, T
    Moretto, P
    Pouthier, A
    Pouthier, T
    Smith, RW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 612 - 617
  • [50] 3D imaging of microscopic structures using a proton beam
    Michelet-Habchi, C
    Incerti, S
    Aguer, P
    Barberet, P
    Gontier, E
    Guinefolleau, T
    Moretto, P
    Pouthier, A
    Pouthier, T
    Smith, RW
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1976 - 1978