3D prompt gamma imaging for proton beam range verification

被引:105
|
作者
Draeger, E. [1 ]
Mackin, D. [2 ]
Peterson, S. [3 ]
Chen, H. [1 ]
Avery, S. [4 ]
Beddar, S. [2 ,5 ]
Polf, J. C. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, 22 South Greene St, Baltimore, MD 21201 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[3] Univ Cape Town, Dept Phys, ZA-7700 Cape Town, South Africa
[4] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd, Philadelphia, PA 19104 USA
[5] Univ Texas Houston, Grad Sch Biomed Sci Houston, 6767 Bertner Ave, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 03期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Compton imaging; prompt gamma; proton therapy; range verification; COMPTON CAMERA; RAY EMISSION; THERAPY; RECONSTRUCTION; RADIOTHERAPY; ENERGY; IRRADIATION; SIMULATION; DETECTORS; RADIATION;
D O I
10.1088/1361-6560/aaa203
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC placed at three different locations along the proton beam path. We evaluated the ability of the CC to produce images at each location for two clinical scenarios: (1) the delivery of a single 2 Gy pencil beam from a hypo-fractionated treatment (similar to 9 x 10(8) protons), and (2) a single pencil beam from a standard treatment (similar to 1 x 10(8) protons). Additionally, the data measured at each location were combined to simulate measurements with a larger scale, clinical CC and its ability to image shifts in the Bragg peak (BP) range for both clinical scenarios. With our prototype CC, the location of the distal end of the BP could be seen with the CC placed up to 4 cm proximal or distal to the BP distal falloff. Using the data from the simulated full scale clinical CC, 3D images of the PG emission were produced with the delivery of as few as 1 x 10(8) protons, and shifts in the proton beam range as small as 2 mm could be detected for delivery of a 2 Gy spot. From these results we conclude that 3D PG imaging for proton range verification under clinical beam delivery conditions is possible with a single CC.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation
    Costanza M. V. Panaino
    Ranald I. Mackay
    Karen J. Kirkby
    Michael J. Taylor
    Scientific Reports, 9
  • [32] Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study
    Biegun, Aleksandra K.
    Seravalli, Enrica
    Lopes, Patricia Cambraia
    Rinaldi, Ilaria
    Pinto, Marco
    Oxley, David C.
    Dendooven, Peter
    Verhaegen, Frank
    Parodi, Katia
    Crespo, Paulo
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6429 - 6444
  • [33] A comparison of two prompt gamma imaging techniques with collimator-based cameras for range verification in proton therapy
    Lin, Hsin-Hon
    Chang, Hao-Ting
    Chao, Tsi-Chian
    Chuang, Keh-Shih
    RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 144 - 150
  • [34] Demonstration of LGADs and Cherenkov Gamma Detectors for Prompt Gamma Timing Proton Therapy Range Verification
    Heller, Ryan
    Ellin, Justin
    Backfish, Michael
    Cates, Joshua W.
    Choong, Woon-Seng
    Kratochwil, Nicolaus
    Prebys, Eric
    Rebolo, Leonor
    St James, Sara
    Arino-Estrada, Gerard
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (04) : 508 - 514
  • [35] Jack Fowler Junior Investigator Competition Winner: First Clinical Prompt Gamma Imaging for in Vivo Range Verification in Pencil Beam Scanning Proton Therapy
    Xie, Y.
    Bentefour, E.
    Janssens, G.
    Smeets, J.
    Vander Stappen, F.
    Hotoiu, L.
    Yin, L.
    Dolney, D.
    Avery, S.
    O'Grady, F.
    Prieels, D.
    McDonough, J.
    Solberg, T.
    Lustig, R.
    Lin, A.
    Teo, B.
    MEDICAL PHYSICS, 2017, 44 (06) : 3258 - 3259
  • [36] Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy
    Shin, H.
    Yoon, D.
    Jung, J.
    Kim, M.
    Jang, H.
    Suh, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3583 - 3583
  • [37] Translation of a prompt gamma based proton range verification system to first clinical application
    Richter, C.
    Pausch, G.
    Barczyk, S.
    Priegnitz, M.
    Golnik, C.
    Bombelli, L.
    Enghardt, W.
    Fiedler, F.
    Fiorini, C.
    Hotoiu, L.
    Janssens, G.
    Keitz, I.
    Mein, S.
    Perali, I.
    Prieels, D.
    Smeets, J.
    Thiele, J.
    Vander Stappen, F.
    Werner, T.
    Baumann, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S214 - S214
  • [38] Prompt gamma timing for proton range verification with TlBr and TlCl as pure Cherenkov emitters
    Ellin, Justin
    Rebolo, Leonor
    Backfish, Michael
    Prebys, Eric
    Arino-Estrada, Gerard
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [39] Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning
    Tian, Liheng
    Huang, Ze
    Janssens, Guillaume
    Landry, Guillaume
    Dedes, George
    Kamp, Florian
    Belka, Claus
    Pinto, Marco
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [40] Experimental Study of Discrete Prompt Gamma Lines for In-Vivo Proton Range Verification
    Verburg, J.
    Riley, K.
    Seco, J.
    MEDICAL PHYSICS, 2013, 40 (06)