A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation

被引:7
|
作者
Panaino, Costanza M. V. [1 ,2 ]
Mackay, Ranald I. [1 ,2 ]
Kirkby, Karen J. [1 ,2 ]
Taylor, Michael J. [1 ,2 ]
机构
[1] Univ Manchester, Div Canc Sci, Manchester M13 9PL, Lancs, England
[2] Christie NHS Fdn Trust, Manchester M20 4BX, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
VIVO RANGE VERIFICATION; COMPTON CAMERA; SCINTILLATION DETECTORS; THERAPY; SIMULATION; ENERGY; UNCERTAINTIES; RADIOTHERAPY; ALGORITHM; SYSTEM;
D O I
10.1038/s41598-019-55349-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A new technique for range verification in proton beam therapy has been developed. It is based on the detection of the prompt gamma rays that are emitted naturally during the delivery of the treatment. A spectrometer comprising 16 LaBr3 (Ce) detectors in a symmetrical configuration is employed to record the prompt gamma rays emitted along the proton path. An algorithm has been developed that takes as inputs the LaBr3 (Ce) detector signals and reconstructs the maximum gamma-ray intensity peak position, in full 3 dimensions. For a spectrometer radius of 8 cm, which could accommodate a paediatric head and neck case, the prompt gamma-ray origin can be determined from the width of the detected peak with a sigma of 4.17 mm for a 180 MeV proton beam impinging a water phantom. For spectrometer radii of 15 and 25 cm to accommodate larger volumes this value increases to 5.65 and 6.36 mm. For a 8 cm radius, with a 5 and 10 mm undershoot, the sigma is 4.31 and 5.47 mm. These uncertainties are comparable to the range uncertainties incorporated in treatment planning. This work represents the first step towards a new accurate, real-time, 3D range verification device for spot-scanning proton beam therapy.
引用
收藏
页数:12
相关论文
共 42 条
  • [1] A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation
    Costanza M. V. Panaino
    Ranald I. Mackay
    Karen J. Kirkby
    Michael J. Taylor
    Scientific Reports, 9
  • [2] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [3] Development of a new prompt gamma ray detection system for full 3D proton range verification
    Costanza, P.
    Mackay, R. I.
    Kirkby, K. J.
    Taylor, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S957 - S958
  • [4] A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05):
  • [5] Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation
    Polf, Jerimy C.
    Panthi, Rajesh
    Mackin, Dennis S.
    McCleskey, Matt
    Saastamoinen, Antti
    Roeder, Brian T.
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (17): : 5821 - 5831
  • [6] Modeling of 3D Positron Emission Activity Distributions Induced by Proton Irradiation: A Semi-Empirical Method
    Lopatiuk-Tirpak, O.
    Su, Z.
    Hsi, W.
    Zeidan, O.
    Meeks, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3705 - 3705
  • [7] CT evaluation of hepatic injury following proton beam irradiation: Appearance, enhancement, and 3D size reduction pattern
    Ahmadi, T
    Itai, Y
    Onaya, H
    Yoshioka, H
    Okumura, T
    Akine, Y
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (05) : 655 - 663
  • [8] Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring
    Lu, Wenzhuo
    Ma, Tianyu
    Yang, Tao
    Xu, Shouping
    Liu, Yaqiang
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] The influence of chemical composition on quenching in proton irradiation of a new deformable 3D dosimeter
    Hoye, E. M.
    Skyt, P. S.
    Balling, P.
    Muren, L. P.
    Swakon, J.
    Mierzwinska, G.
    Rydygier, M.
    Taasti, V.
    Petersen, J. B. B.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S50 - S51
  • [10] Determine Proton Pencil Beam Bragg Peak Position in 3D Through Acoustic Triangulation Algorithm
    Nie, W.
    Sohn, J.
    Li, S.
    Yang, X.
    Liu, T.
    Kassaee, A.
    Sehgal, C.
    Avery, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E268 - E268