A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation

被引:7
|
作者
Panaino, Costanza M. V. [1 ,2 ]
Mackay, Ranald I. [1 ,2 ]
Kirkby, Karen J. [1 ,2 ]
Taylor, Michael J. [1 ,2 ]
机构
[1] Univ Manchester, Div Canc Sci, Manchester M13 9PL, Lancs, England
[2] Christie NHS Fdn Trust, Manchester M20 4BX, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
VIVO RANGE VERIFICATION; COMPTON CAMERA; SCINTILLATION DETECTORS; THERAPY; SIMULATION; ENERGY; UNCERTAINTIES; RADIOTHERAPY; ALGORITHM; SYSTEM;
D O I
10.1038/s41598-019-55349-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A new technique for range verification in proton beam therapy has been developed. It is based on the detection of the prompt gamma rays that are emitted naturally during the delivery of the treatment. A spectrometer comprising 16 LaBr3 (Ce) detectors in a symmetrical configuration is employed to record the prompt gamma rays emitted along the proton path. An algorithm has been developed that takes as inputs the LaBr3 (Ce) detector signals and reconstructs the maximum gamma-ray intensity peak position, in full 3 dimensions. For a spectrometer radius of 8 cm, which could accommodate a paediatric head and neck case, the prompt gamma-ray origin can be determined from the width of the detected peak with a sigma of 4.17 mm for a 180 MeV proton beam impinging a water phantom. For spectrometer radii of 15 and 25 cm to accommodate larger volumes this value increases to 5.65 and 6.36 mm. For a 8 cm radius, with a 5 and 10 mm undershoot, the sigma is 4.31 and 5.47 mm. These uncertainties are comparable to the range uncertainties incorporated in treatment planning. This work represents the first step towards a new accurate, real-time, 3D range verification device for spot-scanning proton beam therapy.
引用
收藏
页数:12
相关论文
共 42 条
  • [21] New noninvasive measurement method of optics parameters in a storage ring using bunch-by-bunch 3D beam position measurement data
    Xu, Xingyi
    Leng, Yongbin
    Zhou, Yimei
    Gao, Bo
    Zhang, Ning
    Chen, Jian
    Cao, Shanshan
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2021, 24 (06):
  • [22] Water and tissue equivalence of a new PRESAGE® formulation for 3D proton beam dosimetry: A Monte Carlo study
    Gorjiara, Tina
    Kuncic, Zdenka
    Doran, Simon
    Adamovics, John
    Baldock, Clive
    MEDICAL PHYSICS, 2012, 39 (11) : 7071 - 7079
  • [23] Method of calibrating response statistics for ML estimation of 3D interaction position in a thick-detector gamma camera
    Hunter, William C. J.
    Barrett, Harrison H.
    Furenlid, Lars R.
    Moore, Stephen K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4359 - +
  • [24] A new e-beam method for grey scale 3D optical elements.
    Kudryashov, VA
    Prewett, PD
    Michette, AG
    MICROELECTRONIC ENGINEERING, 1999, 46 (1-4) : 209 - 212
  • [25] 3D interfraction position verification for patients undergoing partial breast irradiation: Comparing digital tomosynthesis to cone-beam CT
    Zhang, J.
    Wu, Q.
    Godfrey, D.
    Yin, F.
    MEDICAL PHYSICS, 2007, 34 (06) : 2607 - 2607
  • [26] Beam position controlling method for 3D optical system and its application in non-planar ring resonators
    Yuan, Jie
    Chen, Meixiong
    Long, Xingwu
    Tan, Yanyang
    Kang, Zhenglong
    Li, Yingying
    OPTICS EXPRESS, 2012, 20 (17): : 19563 - 19579
  • [27] A study on a nonlinear least-squares fitting method for 3D positioning of gamma rays based on monolithic crystal and SiPM array
    Zhang, Hongfan
    Zhou, Rong
    Yao, Rutao
    Yang, Chaowen
    Xu, Su
    Shu, Yijia
    Jiang, Bing
    Liu, Lang
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2022, 6 (03) : 375 - 390
  • [28] A study on a nonlinear least-squares fitting method for 3D positioning of gamma rays based on monolithic crystal and SiPM array
    Hongfan Zhang
    Rong Zhou
    Rutao Yao
    Chaowen Yang
    Su Xu
    Yijia Shu
    Bing Jiang
    Lang Liu
    Radiation Detection Technology and Methods, 2022, 6 : 375 - 390
  • [29] A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits
    Baek, Jongduk
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2010, 37 (10) : 5351 - 5360
  • [30] Measurements of Gamma Rays above 3 MeV using 3D Position-Sensitive 20x20x15 mm3 CdZnTe Detectors
    Boucher, Yvan A.
    Zhang, Feng
    Kaye, Willy
    He, Zhong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4540 - 4544