Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation

被引:19
|
作者
Schmalgemeier, Heidi [1 ]
Bitter, Thomas [1 ]
Bartsch, Stephan [1 ]
Bullert, Kevin [1 ]
Fischbach, Thomas [1 ]
Eckert, Siegfried [1 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
机构
[1] Ruhr Univ Bochum, Univ Hosp, Heart & Diabet Ctr N Rhine Westphalia, Dept Cardiol, D-32545 Bad Oeynhausen, Germany
关键词
Pulse transit time; Arterial blood pressure measurement; Continuous positive airway pressure (CPAP); Sleep disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HEART-FAILURE; RISK; ECG;
D O I
10.1007/s11325-011-0609-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of the present study was to validate noninvasive, continuous blood pressure (BP) measurement using pulse transit time (PTT) to represent absolute values and detect BP changes under continuous positive airway pressure (CPAP) treatment. We applied CPAP to 78 patients of a cardiological sleep lab using 0 (baseline), 4, 8, and 12 cmH(2)O for 10 min at every level and measured BP simultaneous via PTT-based method and standard oscillometric method (OM). Quality of signal perception was acceptable to convert PTT into BP values in 64 patients (82%). When comparing both methods, we found a strong linear correlation of systolic and diastolic BP (baseline, r = 0.94 for systolic BP; r = 0.95 for diastolic BP, p < 0.001) while no significant differences between absolute values obtained with OM and PTT measurement. Mean bias at baseline was 4.1 +/- 3.2 mmHg for systolic BP and 2.3 +/- 2.2 mmHg for diastolic BP. With increasing CPAP levels, PTT and OM measurements differed continuously up to a systolic difference of 6.6 +/- 4.9 mmHg and a diastolic difference of 4.4 +/- 3.5 mmHg. There was no definite trend of PTT method to either over- or underestimate BP. We found that PTT- and OM-based BP results are closely correlated while applying CPAP over a period of 40 min. With higher CPAP level, bias between both methods increased.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 50 条
  • [11] CONTINUOUS AND NON-INVASIVE BLOOD PRESSURE MEASUREMENT BASED ON PULSE TRANSIT TIME COMPARED TO AMBULATORY BLOOD PRESSURE MEASUREMENT
    Haberl, R.
    Wesely, M.
    Thimel, K.
    Gehring, J.
    Kuechler, G.
    JOURNAL OF HYPERTENSION, 2016, 34 : E287 - E287
  • [12] Blood Pressure Measurement from Photo-plethysmography to Pulse Transit Time
    Myint, C. Z.
    Lim, King Hann
    Wong, Kiing Ing
    Gopalai, Alpha Agape
    Oo, Min Zin
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 496 - 501
  • [13] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [14] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [15] Perturbationless Calibration of Pulse Transit Time to Blood Pressure
    Gao, Mingwu
    Mukkamala, Ramakrishna
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 232 - 235
  • [16] Limitation of Pulse Transit Time to Estimate Blood Pressure
    Sklarsky, Amanda
    Garvin, Nathan M.
    Pawelczyk, James A.
    FASEB JOURNAL, 2019, 33
  • [17] Validation of Pulse Transit Time Based Blood Pressure Estimation on Atrial Fibrillation Patients
    Chen, Yang
    Huang, Shoulin
    Wang, Tong
    Ma, Ting
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2679 - 2682
  • [18] Airway pressure release and biphasic intermittent positive airway pressure ventilation: Are they ready for prime time?
    Seymour, Christopher W.
    Frazer, Michael
    Reilly, Patrick M.
    Fuchs, Barry D.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 62 (05): : 1298 - 1308
  • [19] Restrictive factors of the measurement accuracy to estimate Blood Pressure with Pulse wave Transit Time
    Chen, X. M.
    Li, Y. B.
    Zhang, Y.
    Deng, N.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING: NEW ADVANCES, 2016, : 435 - 441
  • [20] An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method
    McCarthy, B. M.
    O'Flynn, B.
    Mathewson, A.
    SENSORS & THEIR APPLICATIONS XVI, 2011, 307