Restrictive factors of the measurement accuracy to estimate Blood Pressure with Pulse wave Transit Time

被引:0
|
作者
Chen, X. M. [1 ]
Li, Y. B. [1 ]
Zhang, Y. [1 ]
Deng, N. [1 ]
机构
[1] Tsinghua Univ, Inst Microelect, Beijing, Peoples R China
关键词
ARRIVAL-TIME;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Pulse wave Transit Time (PTT) is a promising approach to achieve a continuous and non-invasive measurement of Blood Pressure (BP). However, compared with invasive and cuff-based methods, the PTT-based method is not accurate enough for some circumstances. In this paper, its major restrictive factors are investigated. According to the experimental results and analysis, the breathing rhythm and movement of subjects have an adverse impact on the detection of the pulse wave. In order to obtain better signals, noise should be eliminated and the time delay resulting from filters should be considered. The validity of PTT detection is a dominating factor of accuracy as well. Furthermore, the measured PTT is not the real PTT from the physiological perspective, which is mainly due to the acquisition difficulty of the pulse wave from the main artery. Finally, the influence of the regulatory mechanism is also analyzed.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [1] Limitation of Pulse Transit Time to Estimate Blood Pressure
    Sklarsky, Amanda
    Garvin, Nathan M.
    Pawelczyk, James A.
    FASEB JOURNAL, 2019, 33
  • [2] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [3] Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
    Lass, J
    Meigas, K
    Karai, D
    Kattai, R
    Kaik, J
    Rossmann, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2239 - 2242
  • [4] Continuous blood pressure measurement based on pulse transit time: a comparison to ambulatory blood pressure measurement
    Kuechler, G.
    Gehring, J.
    Wesely, M.
    Thimel, K.
    Haberl, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1267 - 1267
  • [5] Pulse Wave Transit Time and Its Relationship with Systolic Blood Pressure
    Zakaria, N. A.
    Sharifmuddin, N. B.
    Ridzwan, W. M. F. Wan Mohd.
    Mahmood, N. H.
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1354 - +
  • [6] PULSE TRANSIT TIME FOR BLOOD PRESSURE MEASUREMENT UNDER POSITIVE AIRWAY PRESSURE VENTILATION
    Schmalgemeier, Heidi
    Bitter, Thomas
    Bartsch, Stephan
    Bullert, Kevin
    Eckert, Siegfried
    Horstkotte, Dieter
    Oldenburg, Olaf
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E619 - E619
  • [7] Blood Pressure Measurement from Photo-plethysmography to Pulse Transit Time
    Myint, C. Z.
    Lim, King Hann
    Wong, Kiing Ing
    Gopalai, Alpha Agape
    Oo, Min Zin
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 496 - 501
  • [8] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [9] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [10] Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation
    Schmalgemeier, Heidi
    Bitter, Thomas
    Bartsch, Stephan
    Bullert, Kevin
    Fischbach, Thomas
    Eckert, Siegfried
    Horstkotte, Dieter
    Oldenburg, Olaf
    SLEEP AND BREATHING, 2012, 16 (04) : 1105 - 1112