Restrictive factors of the measurement accuracy to estimate Blood Pressure with Pulse wave Transit Time

被引:0
|
作者
Chen, X. M. [1 ]
Li, Y. B. [1 ]
Zhang, Y. [1 ]
Deng, N. [1 ]
机构
[1] Tsinghua Univ, Inst Microelect, Beijing, Peoples R China
关键词
ARRIVAL-TIME;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Pulse wave Transit Time (PTT) is a promising approach to achieve a continuous and non-invasive measurement of Blood Pressure (BP). However, compared with invasive and cuff-based methods, the PTT-based method is not accurate enough for some circumstances. In this paper, its major restrictive factors are investigated. According to the experimental results and analysis, the breathing rhythm and movement of subjects have an adverse impact on the detection of the pulse wave. In order to obtain better signals, noise should be eliminated and the time delay resulting from filters should be considered. The validity of PTT detection is a dominating factor of accuracy as well. Furthermore, the measured PTT is not the real PTT from the physiological perspective, which is mainly due to the acquisition difficulty of the pulse wave from the main artery. Finally, the influence of the regulatory mechanism is also analyzed.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [21] A novel calibration method for noninvasive blood pressure measurement using pulse transit time
    Yan, Y. S.
    Zhang, Y. T.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 1 - +
  • [22] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [23] Perturbationless Calibration of Pulse Transit Time to Blood Pressure
    Gao, Mingwu
    Mukkamala, Ramakrishna
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 232 - 235
  • [24] Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement
    Patzak, Andreas
    Mendoza, Yuri
    Gesche, Heiko
    Konermann, Martin
    BLOOD PRESSURE, 2015, 24 (04) : 217 - 221
  • [25] The impact of pulse pressure on the accuracy of wrist blood pressure measurement
    T H Westhoff
    S Schmidt
    R Meissner
    W Zidek
    M van der Giet
    Journal of Human Hypertension, 2009, 23 : 391 - 395
  • [26] The impact of pulse pressure on the accuracy of wrist blood pressure measurement
    Westhoff, T. H.
    Schmidt, S.
    Meissner, R.
    Zidek, W.
    van der Giet, M.
    JOURNAL OF HUMAN HYPERTENSION, 2009, 23 (06) : 391 - 395
  • [27] Method of optical self-mixing for pulse wave transit time measurement in comparison with other methods and correlation with blood pressure
    Meigas, K
    Lass, J
    Kattai, R
    Karai, D
    Kaik, J
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 444 - 453
  • [28] Blood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar
    Buxi, Dilpreet
    Redout, Jean-Michel
    Yuce, Mehmet Rasit
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) : 917 - 927
  • [29] Cuff-less blood pressure measurement with pulse transit time: The importance of rigorous assessment
    van Helmond, Noud
    Plante, Timothy B.
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (01): : 71 - 72
  • [30] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
    Zhang, Guanqun
    Gao, Mingwu
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) : 1681 - 1686