Restrictive factors of the measurement accuracy to estimate Blood Pressure with Pulse wave Transit Time

被引:0
|
作者
Chen, X. M. [1 ]
Li, Y. B. [1 ]
Zhang, Y. [1 ]
Deng, N. [1 ]
机构
[1] Tsinghua Univ, Inst Microelect, Beijing, Peoples R China
关键词
ARRIVAL-TIME;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Pulse wave Transit Time (PTT) is a promising approach to achieve a continuous and non-invasive measurement of Blood Pressure (BP). However, compared with invasive and cuff-based methods, the PTT-based method is not accurate enough for some circumstances. In this paper, its major restrictive factors are investigated. According to the experimental results and analysis, the breathing rhythm and movement of subjects have an adverse impact on the detection of the pulse wave. In order to obtain better signals, noise should be eliminated and the time delay resulting from filters should be considered. The validity of PTT detection is a dominating factor of accuracy as well. Furthermore, the measured PTT is not the real PTT from the physiological perspective, which is mainly due to the acquisition difficulty of the pulse wave from the main artery. Finally, the influence of the regulatory mechanism is also analyzed.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [31] Methods for Continuous Non-invasive Measurement of Blood Pressure: Pulse Transit Time a Review
    Kaur, Harleen
    Bhutto, Javed Khan
    Choudhary, Bhawani Shankar
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (03) : S863 - S872
  • [32] Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm
    Ding, Xiaorong
    Zhang, Yuan-Ting
    BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) : 37 - 52
  • [33] Continuous and Noninvasive Blood Pressure Estimation by Two-Sensor Measurement of Pulse Transit Time
    Rasool, Anam
    Rafiq, Muqudas
    Nasir, Aisha
    Kashif, Faisal M.
    2018 14TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2018,
  • [34] Blood pressure measurement based on pulse transit time from different positioned photoplethysmography signals
    Kao, Yu Cheng
    Wang, Chun-Hsiung
    Lee, Shu-Sheng
    Wu, Wen-Jong
    Lee, Chih-Kung
    TISSUE OPTICS AND PHOTONICS, 2020, 11363
  • [35] Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm
    Xiaorong Ding
    Yuan-Ting Zhang
    Biomedical Engineering Letters, 2019, 9 : 37 - 52
  • [36] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [37] Evaluation of the Correlation Between Blood Pressure and Pulse Transit Time
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 17 - 20
  • [38] PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE
    OBRIST, PA
    LIGHT, KC
    MCCUBBIN, JA
    HUTCHESON, JS
    HOFFER, JL
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1978, 10 (05): : 623 - 626
  • [39] A Compensation Method for Blood Pressure Estimation by Pulse Transit Time
    Liu, Songsong
    Ma, Heather T.
    Chen, Long
    Wang, Xiaopeng
    Yuan, Dezhang
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [40] Blood Pressure Estimation Based on Pulse Transit Time with LANDMARC
    Wang, Yang
    Liu, Zhiwen
    2017 IEEE LIFE SCIENCES CONFERENCE (LSC), 2017, : 141 - 144