Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation

被引:19
|
作者
Schmalgemeier, Heidi [1 ]
Bitter, Thomas [1 ]
Bartsch, Stephan [1 ]
Bullert, Kevin [1 ]
Fischbach, Thomas [1 ]
Eckert, Siegfried [1 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
机构
[1] Ruhr Univ Bochum, Univ Hosp, Heart & Diabet Ctr N Rhine Westphalia, Dept Cardiol, D-32545 Bad Oeynhausen, Germany
关键词
Pulse transit time; Arterial blood pressure measurement; Continuous positive airway pressure (CPAP); Sleep disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HEART-FAILURE; RISK; ECG;
D O I
10.1007/s11325-011-0609-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of the present study was to validate noninvasive, continuous blood pressure (BP) measurement using pulse transit time (PTT) to represent absolute values and detect BP changes under continuous positive airway pressure (CPAP) treatment. We applied CPAP to 78 patients of a cardiological sleep lab using 0 (baseline), 4, 8, and 12 cmH(2)O for 10 min at every level and measured BP simultaneous via PTT-based method and standard oscillometric method (OM). Quality of signal perception was acceptable to convert PTT into BP values in 64 patients (82%). When comparing both methods, we found a strong linear correlation of systolic and diastolic BP (baseline, r = 0.94 for systolic BP; r = 0.95 for diastolic BP, p < 0.001) while no significant differences between absolute values obtained with OM and PTT measurement. Mean bias at baseline was 4.1 +/- 3.2 mmHg for systolic BP and 2.3 +/- 2.2 mmHg for diastolic BP. With increasing CPAP levels, PTT and OM measurements differed continuously up to a systolic difference of 6.6 +/- 4.9 mmHg and a diastolic difference of 4.4 +/- 3.5 mmHg. There was no definite trend of PTT method to either over- or underestimate BP. We found that PTT- and OM-based BP results are closely correlated while applying CPAP over a period of 40 min. With higher CPAP level, bias between both methods increased.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 50 条
  • [41] Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
    Lass, J
    Meigas, K
    Karai, D
    Kattai, R
    Kaik, J
    Rossmann, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2239 - 2242
  • [42] CARDIOVASCULAR EFFECTS OF CONVENTIONAL POSITIVE PRESSURE VENTILATION AND AIRWAY PRESSURE RELEASE VENTILATION
    RASANEN, J
    DOWNS, JB
    STOCK, MC
    CHEST, 1988, 93 (05) : 911 - 915
  • [43] Clinical review: Biphasic positive airway pressure and airway pressure release ventilation
    Christian Putensen
    Hermann Wrigge
    Critical Care, 8
  • [44] Clinical review: Biphasic positive airway pressure and airway pressure release ventilation
    Putensen, C
    Wrigge, H
    CRITICAL CARE, 2004, 8 (06): : 492 - 497
  • [45] Airway pressure release and biphasic intermittent positive airway pressure ventilation: Are they ready for prime time? Editorial comment
    Kaplan, Lewis J.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 62 (05): : 1308 - 1309
  • [46] Can pulse transit time-estimated blood pressure become a savior for blood pressure research?
    Ohishi, Mitsuru
    HYPERTENSION RESEARCH, 2022, 45 (06) : 1070 - 1071
  • [47] Can pulse transit time-estimated blood pressure become a savior for blood pressure research?
    Mitsuru Ohishi
    Hypertension Research, 2022, 45 : 1070 - 1071
  • [48] Validation of the Inverse Pulse Wave Transit Time Series as Surrogate of Systolic Blood Pressure in MVAR Modeling
    Giassi, Pedro, Jr.
    Okida, Sergio
    Oliveira, Mauricio G.
    Moraes, Raimes
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (11) : 3176 - 3184
  • [49] Effect of airway pressure on lumbar epidural pressure during positive pressure ventilation
    Han, Sun Sook
    Lim, Young Jin
    Jeon, Yunseok
    Min, Kyoung-Beom
    Ahn, Won-Sik
    Lee, Sang Chul
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 61 (02) : 138 - 142
  • [50] Noninvasive Cuffless Blood Pressure Measurement by Vascular Transit Time
    Shukla, Satya Narayan
    Kakwani, Karan
    Patra, Amit
    Lahkar, Bipin Kumar
    Gupta, Vivek Kumar
    Jayakrishna, Alwar
    Vashisht, Puneet
    Sreekanth, Induja
    2015 28TH INTERNATIONAL CONFERENCE ON VLSI DESIGN (VLSID), 2015, : 535 - 540