Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter

被引:4
|
作者
Murakawa, Hideki [1 ]
Ichimura, Shuhei [1 ]
Shimada, Masaki [1 ]
Sugimoto, Katsumi [1 ]
Asano, Hitoshi [1 ]
Umezawa, Shuichi [2 ]
Sugita, Katsuhiko [2 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[2] Tokyo Elect Power Co Holdings Inc, Tsurumi Ku, 4-1 Egasaki, Yokohama, Kanagawa 2308510, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2020年 / 7卷 / 04期
关键词
Steam flow rate; Clamp-on; Ultrasonic flowmeter; Time-of-flight; Incident angle; Lamb wave;
D O I
10.1299/mej.20-00131
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Energy management in industrial plants requires measurements of the steam flow rates at each usage location. A clamp-on ultrasonic flowmeter can be used to effectively measure the steam flow rates in existing pipes. An ultrasonic flowmeter is used to calculate the transit time of ultrasonic signals between the downstream and upstream sensors, which is affected by the line-averaged velocity along the ultrasonic beam. The intensity of the transmitted ultrasonic signal is crucial for measuring the steam flow rate using the clamp-on ultrasonic flowmeter. The authors focused on the effects of the ultrasonic incident angle on the transmitted ultrasonic signal intensity in steam flow. Ultrasonic transmission experiments were carried out on three pipes (SGP 25A, SGP 50A and SGP 80A) filled with stationary nitrogen, and the transit time in steam flow was measured on SGP 80A pipe by changing the ultrasonic incident angle. The pipes are made of carbon steel and generally used for the steam flow. The results indicate that the appropriate incident angle that allowed the maximum transmitted signal intensity differed depending on the thickness of the pipe wall. Furthermore, a good agreement with the critical angles of the zero-order of symmetric mode in Lamb waves was noted. Thus, the propagated ultrasonic waves can be considered Lamb waves, which increase signal intensity. The transmitted signal intensity decreases because of the turbulent dissipation as the steam velocity increases. Appropriately setting the incident angle depending on the wall thickness, particularly for higher steam flow rates, is essential for evaluating the transit time difference between upstream and downstream transducers.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Flow disturbance compensation calculated with flow simulations for ultrasonic clamp-on flowmeters with optimized path arrangement
    Papathanasiou, Panagiotis
    Kissling, Beat
    Berberig, Oliver
    Kumar, Vivek
    Rohner, Adrian
    Bezdek, Michal
    FLOW MEASUREMENT AND INSTRUMENTATION, 2022, 85
  • [42] Design and Proof-of-Concept of a Matrix Transducer Array for Clamp-On Ultrasonic Flow Measurements
    Massaad, Jack
    Van Neer, Paul L. M. J.
    Van Willigen, Douwe M.
    Noothout, Emile C.
    de Jong, Nicolaas
    Pertijs, Michiel A. P.
    Verweij, Martin D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (08) : 2555 - 2568
  • [43] The uncertainties induced by internal pipe wall roughness on the measurements of clamp-on ultrasonic flow meters
    Gu, Xiaotang
    Cegla, Frederic
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1586 - 1589
  • [44] Influence of Flow Disturbances behind the 90° Bend on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
    Synowiec, Piotr
    Andruszkiewicz, Artur
    Wedrychowicz, Wieslaw
    Piechota, Piotr
    Wroblewska, Elzbieta
    SENSORS, 2021, 21 (03) : 1 - 23
  • [45] Improving interference immunity of ultrasonic gas flowmeters with clamp-on probes
    Mansfeld, A. D.
    Volkov, G. P.
    Agureev, V. A.
    Trusillo, S. V.
    Karyuk, V. M.
    Moroskin, D. V.
    AUTOMATION AND REMOTE CONTROL, 2013, 74 (02) : 301 - 307
  • [46] Analysis of ultrasound propagation in high-temperature nuclear reactor feedwater to investigate a clamp-on ultrasonic pulse Doppler flowmeter
    Tezuka, Kenichi
    Mori, Michitsugu
    Wada, Sanehiro
    Aritomi, Masanori
    Kikura, Hiroshige
    Sakai, Yukihiro
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, 45 (08) : 752 - 762
  • [47] WHAT YOU SHOULD KNOW ABOUT CLAMP-ON ULTRASONIC FLOWMETERS
    SCHMIDT, TR
    INSTRUMENTATION TECHNOLOGY, 1981, 28 (05): : 59 - 62
  • [48] Improving interference immunity of ultrasonic gas flowmeters with clamp-on probes
    A. D. Mansfeld
    G. P. Volkov
    V. A. Agureev
    S. V. Trusillo
    V. M. Karyuk
    D. V. Moroskin
    Automation and Remote Control, 2013, 74 : 301 - 307
  • [49] Application of ultrasonic clamp-on flow meters for in situ tests of billing meters in district heating systems
    Svensson, B
    Delsing, J
    FLOW MEASUREMENT AND INSTRUMENTATION, 1998, 9 (01) : 33 - 41
  • [50] Measurement of Pipe and Fluid Properties With a Matrix Array-Based Ultrasonic Clamp-On Flow Meter
    Massaad, Jack
    van Neer, Paul L. M. J.
    van Willigen, Douwe M.
    Sabbadini, Alberico
    de Jong, Nicolaas
    Pertijs, Michiel A. P.
    Verweij, Martin D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (01) : 309 - 322