Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter

被引:4
|
作者
Murakawa, Hideki [1 ]
Ichimura, Shuhei [1 ]
Shimada, Masaki [1 ]
Sugimoto, Katsumi [1 ]
Asano, Hitoshi [1 ]
Umezawa, Shuichi [2 ]
Sugita, Katsuhiko [2 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[2] Tokyo Elect Power Co Holdings Inc, Tsurumi Ku, 4-1 Egasaki, Yokohama, Kanagawa 2308510, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2020年 / 7卷 / 04期
关键词
Steam flow rate; Clamp-on; Ultrasonic flowmeter; Time-of-flight; Incident angle; Lamb wave;
D O I
10.1299/mej.20-00131
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Energy management in industrial plants requires measurements of the steam flow rates at each usage location. A clamp-on ultrasonic flowmeter can be used to effectively measure the steam flow rates in existing pipes. An ultrasonic flowmeter is used to calculate the transit time of ultrasonic signals between the downstream and upstream sensors, which is affected by the line-averaged velocity along the ultrasonic beam. The intensity of the transmitted ultrasonic signal is crucial for measuring the steam flow rate using the clamp-on ultrasonic flowmeter. The authors focused on the effects of the ultrasonic incident angle on the transmitted ultrasonic signal intensity in steam flow. Ultrasonic transmission experiments were carried out on three pipes (SGP 25A, SGP 50A and SGP 80A) filled with stationary nitrogen, and the transit time in steam flow was measured on SGP 80A pipe by changing the ultrasonic incident angle. The pipes are made of carbon steel and generally used for the steam flow. The results indicate that the appropriate incident angle that allowed the maximum transmitted signal intensity differed depending on the thickness of the pipe wall. Furthermore, a good agreement with the critical angles of the zero-order of symmetric mode in Lamb waves was noted. Thus, the propagated ultrasonic waves can be considered Lamb waves, which increase signal intensity. The transmitted signal intensity decreases because of the turbulent dissipation as the steam velocity increases. Appropriately setting the incident angle depending on the wall thickness, particularly for higher steam flow rates, is essential for evaluating the transit time difference between upstream and downstream transducers.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Study on the Influences of Multiple Parameters With Uncertainty in the Clamp-On Ultrasonic Flowmeter
    Shi, Huichao
    Kang, Xirui
    He, Shuman
    Meng, Tao
    IEEE ACCESS, 2020, 8 : 183787 - 183798
  • [12] Novel FMCW-Interferometry Method Testing on an Ultrasonic Clamp-On Flowmeter
    Ronkin, Mikhail
    Kalmykov, Alexey
    Zeyde, Kirill
    IEEE SENSORS JOURNAL, 2020, 20 (11) : 6029 - 6037
  • [13] Automatic Calibration of Clamp-on Ultrasonic Flowmeter Based on Fieldbus Control System
    Hou Qingqiang
    Huang Yongmei
    Zhang Zhiliang
    Sun Bin
    ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 : 1730 - +
  • [14] Similarity model for estimating the error of clamp-on ultrasonic flowmeter: Flow in water supply piping system
    Sritham, Earasit
    Wachirapunyanont, Rathachot
    Siriparinyanan, Pontakorn
    Nunak, Navaphattra
    Suesut, Taweepol
    Engineering Letters, 2017, 25 (03) : 239 - 246
  • [15] Mathematical modelling of ultrasonic flow meters with clamp-on transducers
    Willatzen, A
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2004, 90 (01) : 70 - 76
  • [16] Design of Miniature Clamp-On Ultrasonic Flow Measurement Transducers
    Li, Zhichao
    Smith, Luke
    Dixon, Steve
    IEEE SENSORS LETTERS, 2021, 5 (06) : 1 - 4
  • [17] Evaluation of the propagation time difference in low-pressure city gas flow using a clamp-on ultrasonic flowmeter
    Nishiguchi, Hiroshi
    Sawayama, Toshiyuki
    Nagamune, Kouki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [18] Noninvasive clamp-on ultrasonic level switch
    不详
    HYDROCARBON PROCESSING, 2002, 81 (05): : 31 - 31
  • [19] CLAMP-ON ULTRASONIC FLOWMETERS - LIMITATIONS AND REMEDIES
    LYNNWORTH, LC
    INSTRUMENTATION TECHNOLOGY, 1975, 22 (09): : 37 - 44
  • [20] Installation Effects of a Clamp-On Transit Time Ultrasonic Flow Meter
    Kumar, K.
    Farande, K. U.
    Sahoo, G. C.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2011, 38 (06) : 489 - 498