Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter

被引:4
|
作者
Murakawa, Hideki [1 ]
Ichimura, Shuhei [1 ]
Shimada, Masaki [1 ]
Sugimoto, Katsumi [1 ]
Asano, Hitoshi [1 ]
Umezawa, Shuichi [2 ]
Sugita, Katsuhiko [2 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[2] Tokyo Elect Power Co Holdings Inc, Tsurumi Ku, 4-1 Egasaki, Yokohama, Kanagawa 2308510, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2020年 / 7卷 / 04期
关键词
Steam flow rate; Clamp-on; Ultrasonic flowmeter; Time-of-flight; Incident angle; Lamb wave;
D O I
10.1299/mej.20-00131
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Energy management in industrial plants requires measurements of the steam flow rates at each usage location. A clamp-on ultrasonic flowmeter can be used to effectively measure the steam flow rates in existing pipes. An ultrasonic flowmeter is used to calculate the transit time of ultrasonic signals between the downstream and upstream sensors, which is affected by the line-averaged velocity along the ultrasonic beam. The intensity of the transmitted ultrasonic signal is crucial for measuring the steam flow rate using the clamp-on ultrasonic flowmeter. The authors focused on the effects of the ultrasonic incident angle on the transmitted ultrasonic signal intensity in steam flow. Ultrasonic transmission experiments were carried out on three pipes (SGP 25A, SGP 50A and SGP 80A) filled with stationary nitrogen, and the transit time in steam flow was measured on SGP 80A pipe by changing the ultrasonic incident angle. The pipes are made of carbon steel and generally used for the steam flow. The results indicate that the appropriate incident angle that allowed the maximum transmitted signal intensity differed depending on the thickness of the pipe wall. Furthermore, a good agreement with the critical angles of the zero-order of symmetric mode in Lamb waves was noted. Thus, the propagated ultrasonic waves can be considered Lamb waves, which increase signal intensity. The transmitted signal intensity decreases because of the turbulent dissipation as the steam velocity increases. Appropriately setting the incident angle depending on the wall thickness, particularly for higher steam flow rates, is essential for evaluating the transit time difference between upstream and downstream transducers.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A novel ultrasonic/thermal clamp-on flowmeter for low liquid flowrates in small diameter pipes
    Guilbert, AR
    Law, M
    Sanderson, ML
    ULTRASONICS, 1996, 34 (2-5) : 435 - 439
  • [22] Clamp-On Ultrasonic System Solves Slurry Flow Measurement Problem
    不详
    E&MJ-ENGINEERING AND MINING JOURNAL, 2009, 210 (08): : 88 - 89
  • [23] Clamp-on Ultrasonic Transducers with Improved Dynamics for Flow Measuring Applications
    Hamidullin, V. K.
    Malakhanov, R. N.
    Degterev, K. B.
    Krysin, D. U.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1026 - +
  • [24] Assessment of combined V/Z clamp-on ultrasonic flow metering
    Sejong Chun
    Byung-Ro Yoon
    Woong Kang
    Hyu-Sang Kwon
    Journal of Mechanical Science and Technology, 2014, 28 : 2169 - 2177
  • [25] Assessment of combined V/Z clamp-on ultrasonic flow metering
    Chun, Sejong
    Yoon, Byung-Ro
    Kang, Woong
    Kwon, Hyu-Sang
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (06) : 2169 - 2177
  • [26] A propagation time difference evaluation for a clamp-on ultrasonic flowmeter for low-pressure gas
    Nishiguchi, Hiroshi
    Sawayama, Toshiyuki
    Nagamune, Kouki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (07)
  • [27] Acoustic Design of a Transducer Array for Ultrasonic Clamp-on Flow Metering
    Massaad, Jack
    van Willigen, Douwe
    van Neer, Paul
    de Jong, Nicolaas
    Pertijs, Michiel
    Verweij, Martin
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1133 - 1136
  • [28] A clamp-on ultrasonic cross correlation flow meter for one-phase flow
    Worch, A
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) : 622 - 630
  • [29] High-temperature flow measurement with wetted and clamp-on ultrasonic sensors
    Lynnworth, Larry
    Sensors (Peterborough, NH), 1999, 16 (10): : 40 - 42
  • [30] Studies on the transducers of Clamp-on Transit-time Ultrasonic Flow meter
    Han, Jianping
    Liu, Hao
    Zhou, Yuanyuan
    Zhang, Rumei
    Li, Changji
    2014 4TH IEEE INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND TECHNOLOGY (ICIST), 2014, : 180 - 183