Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter

被引:4
|
作者
Murakawa, Hideki [1 ]
Ichimura, Shuhei [1 ]
Shimada, Masaki [1 ]
Sugimoto, Katsumi [1 ]
Asano, Hitoshi [1 ]
Umezawa, Shuichi [2 ]
Sugita, Katsuhiko [2 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[2] Tokyo Elect Power Co Holdings Inc, Tsurumi Ku, 4-1 Egasaki, Yokohama, Kanagawa 2308510, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2020年 / 7卷 / 04期
关键词
Steam flow rate; Clamp-on; Ultrasonic flowmeter; Time-of-flight; Incident angle; Lamb wave;
D O I
10.1299/mej.20-00131
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Energy management in industrial plants requires measurements of the steam flow rates at each usage location. A clamp-on ultrasonic flowmeter can be used to effectively measure the steam flow rates in existing pipes. An ultrasonic flowmeter is used to calculate the transit time of ultrasonic signals between the downstream and upstream sensors, which is affected by the line-averaged velocity along the ultrasonic beam. The intensity of the transmitted ultrasonic signal is crucial for measuring the steam flow rate using the clamp-on ultrasonic flowmeter. The authors focused on the effects of the ultrasonic incident angle on the transmitted ultrasonic signal intensity in steam flow. Ultrasonic transmission experiments were carried out on three pipes (SGP 25A, SGP 50A and SGP 80A) filled with stationary nitrogen, and the transit time in steam flow was measured on SGP 80A pipe by changing the ultrasonic incident angle. The pipes are made of carbon steel and generally used for the steam flow. The results indicate that the appropriate incident angle that allowed the maximum transmitted signal intensity differed depending on the thickness of the pipe wall. Furthermore, a good agreement with the critical angles of the zero-order of symmetric mode in Lamb waves was noted. Thus, the propagated ultrasonic waves can be considered Lamb waves, which increase signal intensity. The transmitted signal intensity decreases because of the turbulent dissipation as the steam velocity increases. Appropriately setting the incident angle depending on the wall thickness, particularly for higher steam flow rates, is essential for evaluating the transit time difference between upstream and downstream transducers.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] First clamp-on ultrasonic mass/velocity meter
    不详
    HYDROCARBON PROCESSING, 2003, 82 (02): : 32 - 32
  • [32] A New Calibration Method for Ultrasonic Clamp-On Transducers
    Keitmann-Curdes, O.
    Funck, B.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 517 - 520
  • [33] New semi three-dimensional approach for simulation of Lamb wave clamp-on ultrasonic gas flowmeter
    Mousavi, Seyed Foad
    Hashemabadi, Seyed Hassan
    Jamali, Jalil
    SENSOR REVIEW, 2020, 40 (04) : 465 - 476
  • [34] The Effect of Internal Pipe Wall Roughness on the Accuracy of Clamp-On Ultrasonic Flowmeters
    Gu, Xiaotang
    Cegla, Frederic
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (01) : 65 - 72
  • [35] 300 degrees C clamp-on ultrasonic transducers for measuring water flow and level
    Lynnworth, LC
    Jossinet, G
    Cherifi, E
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 407 - 412
  • [36] Liquid Flow Measurement Using Silicone Polymer Wedge Clamp-On Ultrasonic Transducers
    Li, Zhichao
    Hughes, Foz
    Kerr, Noel C.
    Wilson, Richard
    Dixon, Steve
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 5157 - 5165
  • [37] Effect of an asymmetric flow disturber on an ultrasonic flowmeter
    Papathanasiou, Panagiotis
    Kissling, Beat
    Kumar, Vivek
    Rohner, Adrian
    Berberig, Oliver
    Bezdek, Michal
    TM-TECHNISCHES MESSEN, 2020, 87 (01) : 3 - 17
  • [38] Studies of the Accuracy of Clamp-on Transit Time Ultrasonic Flowmeters
    Mahadeva, D. V.
    Baker, R. C.
    Woodhouse, J.
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 969 - 973
  • [39] Hydroelectric Plant Benefits from Ultrasonic Clamp-on Measurement
    Norinder, Jonas
    POWER ENGINEERING, 2011, 115 (03) : 20 - 22
  • [40] Clamp-on ultrasonic meter economically gauges multiphase flows
    Al-Lababidi, S., 1600, Oildom Publishing Co. of Texas Inc. (232):